C0.5, C0.7, C1.1, C1.5, C1.6 and C2.2 Industrial Engines Caterpillar


Electrical System

Usage:

C0.5 C6F

Engine Electrical System



Illustration 1g01339089
(1) Warning lamp (alternator)
(2) Warning lamp (oil pressure)
(3) Warning lamp (coolant temperature)
(4) Fuel shutoff solenoid
(5) Alternator
(6) Engine oil pressure switch
(7) Coolant temperature switch
(8) Glow plugs
(9) Signal for glow plugs
(10) Ignition switch
(11) Electric starting motor
(12) Battery

The electrical system has two separate circuits.

  • Charging circuit

  • Starting circuit

Some of the electrical system components are used in more than one circuit. The following items are common in each of the circuits:

  • Battery

  • Circuit breaker

  • Cables

  • Wires for the battery

The charging circuit is in operation when the engine is running. An alternator converts mechanical energy to electrical energy for the charging circuit. A voltage regulator in the circuit controls the electrical output in order to keep the battery at full charge.


NOTICE

The disconnect switch, if equipped, must be in the ON position in order to let the electrical system function. There will be damage to some of the charging circuit components if the engine is running with the disconnect switch in the OFF position.


If the engine has a disconnect switch, the starting circuit can operate only after the disconnect switch is put in the "ON" position.

The starting switch is in operation only when the start switch is activated.

The charging circuit is connected through the ammeter. The starting circuit is not connected through the ammeter.

Automatic Shutdown System

Wiring Diagram for a 15 Amp Alternator



Illustration 2g01339109
(1) Warning lamp (alternator)
(2) Regulator
(3) Alternator
(4) Battery
(5) Electric starting motor
(6) Warning lamp (oil pressure)
(7) Engine oil pressure switch
(8) Warning lamp (coolant temperature)
(9) Coolant temperature switch
(10) Fuse
(11) Ignition switch
(12) Signal for glow plugs
(13) Glow plugs
(14) Fuel shutoff solenoid
(15) Automatic shutdown device
(16) Electrical connector
(17) Delay fuse

Wiring Diagram for a 40 Amp Alternator



Illustration 3g00916844
(1) Warning lamp (alternator)
(2) Alternator
(3) Battery
(4) Electric starting motor
(5) Warning lamp (oil pressure)
(6) Engine oil pressure switch
(7) Warning lamp (coolant temperature)
(8) Coolant temperature switch
(9) Fuse
(10) Fuse
(11) Ignition switch
(12) Signal for glow plug
(13) Glow plugs
(14) Fuel shutoff solenoid
(15) Automatic shutdown device
(16) Electrical connector
(17) Delay fuse

Wiring Diagram for a 55 Amp Alternator



Illustration 4g00916845
(1) Warning lamp (alternator)
(2) Alternator
(3) Battery
(4) Electric starting motor
(5) Warning lamp (oil pressure)
(6) Engine oil pressure switch
(7) Warning lamp (coolant temperature)
(8) Coolant temperature switch
(9) Fuse
(10) Ignition switch
(11) Signal for glow plug
(12) Glow plugs
(13) Fuel shutoff solenoid
(14) Automatic shutdown device
(15) Electrical connector

Wiring Diagram for a 65 Amp Alternator and a 85 Amp Alternator



Illustration 5g01519204
(1) Warning lamp (alternator)
(2) Alternator
(3) Battery
(4) Electric starting motor
(5) Tachometer
(6) Warning lamp (oil pressure)
(7) Engine oil pressure switch
(8) Warning lamp (coolant temperature)
(9) Coolant temperature switch
(10) Fuse
(11) Ignition switch
(12) Signal for glow plug
(13) Glow plugs
(14) Fuel shutoff solenoid
(15) Automatic shutdown device
(16) Electrical connector

Electrical Connector



Illustration 6g00841411
Connector for the automatic shutdown device (typical example)
(1) Ignition switch (red wire)
(2) Ignition switch (orange wire)
(3) Fuel shutoff solenoid (red and black wire)
(4) Engine oil pressure switch (brown wire)
(5) Coolant temperature switch (blue wire)
(6) Ground (black wire)

Automatic Shutdown Conditions

The engine will shut down if the following conditions continue for more than 10 seconds while you start the engine or for 2 seconds while you operate the engine:

Coolant temperature exceeds the following values:

All engines ... 110° ± 3°C (230° ± 5°F)

Engine oil pressure falls below the following values:

Engine oil pressure switch that is located on the valve mechanism cover ... 29 kPa (4.27 psi)
Engine oil pressure switch that is located on the cylinder block ... 98 kPa (14.22 psi)

Note: There is no automatic shutdown for low coolant level.

Note: The capacity of the diode must be 3 A with a reverse voltage of 600 V.

Note: The rated current draw of the engine oil pressure switch is 0.42 A (5 W maximum bulb).

Note: If necessary, a delay fuse should be used for replacement.

Charging System Components


NOTICE

Never operate the alternator without the battery in the circuit. Making or breaking an alternator connection with heavy load on the circuit can cause damage to the regulator.


Alternator



Illustration 7g00292313
Alternator
(1) Regulator
(2) Roller bearing
(3) Stator winding
(4) Ball bearing
(5) Rectifier bridge
(6) Field winding
(7) Rotor assembly
(8) Fan

The alternator is driven by the crankshaft pulley through a belt. When the engine is running, the pulley rotates the shaft inside the alternator. The rotor assembly is attached to the shaft. The rotor assembly has many magnetic poles. The magnetic poles are similar to fingers. An air space exists between each of the opposite poles. The poles have residual magnetism that produces a small amount of magnet-like lines of force (magnetic field). This magnetic field is produced between the poles. As the rotor assembly begins to turn between the field winding and the stator windings, a small amount of alternating current (AC) is produced in the stator windings. The alternating current is produced from the small magnetic lines of force that are created by the residual magnetism of the poles. The AC is changed into direct current (DC) when the current passes through the diodes of the rectifier bridge. Most of this current provides the battery charge and the supply for the low amperage circuit. The remainder of the current is sent to the field windings. The DC current flow through the field windings (wires around an iron core) increases the strength of the magnetic lines of force. These stronger magnetic lines of force increase the amount of AC that is produced in the stator windings. The increased speed of the rotor assembly also increases the current output of the alternator and the voltage output of the alternator.

Regulator



Illustration 8g00360155
Typical regulator assembly

The voltage regulator is a solid-state electronic switch. The voltage regulator senses the voltage of the system. The regulator then uses switches to control the current to the field windings. This controls the voltage output in order to meet the electrical demand of the system.

Starting System Components

Solenoid



Illustration 9g00292316
Typical solenoid schematic

A solenoid is an electromagnetic switch that performs two basic functions:

  • The solenoid closes the high current starting motor circuit with a low current start switch circuit.

  • The solenoid engages the starting motor pinion with the ring gear.

The solenoid has windings (one set or two sets) around a hollow cylinder. A plunger with a spring load device is inside of the cylinder. The plunger can move forward and backward. When the start switch is closed and electricity is sent through the windings, a magnetic field is created. The magnetic field pulls the plunger forward in the cylinder. This moves the shift lever in order for the pinion drive gear to engage with the ring gear. The front end of the plunger then makes contact across the battery and across the motor terminals of the solenoid. The starting motor then begins to turn the flywheel of the engine.

When the start switch is opened, current no longer flows through the windings. The spring now returns the plunger to the original position. At the same time, the spring moves the pinion gear away from the flywheel.

When two sets of windings in the solenoid are used, the windings are called the hold-in winding and the pull-in winding. Both of the windings wind around the cylinder for an equal amount of times. The pull-in winding uses a wire with a larger diameter in order to produce a stronger magnetic field. When the start switch is closed, part of the current flows from the battery through the hold-in winding. The remainder of the current flows through the pull-in windings, to the motor terminal, and then to the ground. When the solenoid is fully activated, the current is shut off through the pull-in windings. Only the smaller hold-in windings are in operation for the extended time period that is necessary for the engine to be started. The solenoid will now take a smaller amount of current from the battery. Heat that is created by the solenoid will be kept at an acceptable level.

Electric Starting Motor



Illustration 10g00292330
Starting motor cross section (typical example)
(1) Field
(2) Solenoid
(3) Clutch
(4) Starter pinion
(5) Commutator
(6) Brush assembly
(7) Armature

The starting motor rotates the engine flywheel at a rate that is fast enough to start the engine.

The starting motor has a solenoid (2). When the start switch is activated, solenoid (2) will move starter pinion (4) in order to engage starter pinion (4) to the ring gear on the engine flywheel. Starter pinion (4) and the ring gear will engage when the circuit between the battery and the starting motor is closed by the electric contacts in solenoid (2). When the circuit between the battery and the starting motor is complete, starter pinion (4) will rotate the engine flywheel. A clutch provides protection for the starting motor so that the engine cannot turn the starting motor too fast. When the switch is released, starter pinion (4) will move away from the ring gear.

Other Components

Circuit Breaker



Illustration 11g00281837
Circuit breaker schematic
(1) Reset button
(2) Disc in open position
(3) Contacts
(4) Disc
(5) Battery circuit terminals

The circuit breaker is a switch that opens the battery circuit if the current in the electrical system is higher than the rating of the circuit breaker. Metal disc (2) is activated by heat. As the current in the electrical system increases, the temperature of metal disc (2) will increase. The heat that is caused by the excessive current will cause a distortion in metal disc (2). When a distortion occurs in metal disc (2), contacts (3) open. A circuit breaker that is open can be reset when the metal disc becomes cooler. Push reset button (1) in order to close contacts (3) and reset the circuit breaker.

Caterpillar Information System:

C4.4 (Mech) Industrial Engine Fuel Injection Lines
C4.4 (Mech) Industrial Engine Camshaft Bearings
C1.1, C1.5 and C2.2 Engines for Caterpillar Built Machines Fuel System
C4.4 (Mech) Industrial Engine Glow Plugs
3500 Engines Air Lines
2007/06/25 Turbocharger Groups have been Improved {1052}
3508B Industrial Engines Air Lines - Air Starting Lines
3508B Industrial Engines Air Lines - Air Starting Lines
C4.4 (Mech) Industrial Engine Engine Oil Pump
C4.4 (Mech) Industrial Engine Main Bearing Journal - Steel Crankshaft
Reuse & Salvage for Valvetrain Components {1102, 1108, 1109, 1121, 1123} Reuse & Salvage for Valvetrain Components {1102, 1108, 1109, 1121, 1123}
TA19-M2WD and TA19-M4WD (Delta) Agricultural Transmission Power Train Electronic Control System Transmission, SPN 739 - FMI 6
C7 and C9 On-Highway Engines Crankcase Pressure Is High
C7 and C9 On-Highway Engines Crankcase Pressure Is Low
C7 and C9 On-Highway Engines ARD Purge Air - Test
3500 Engines Air Lines
C13 and C15 On-highway Engines Electronic Service Tool Does Not Communicate
3126E and 3126B Commercial and Truck Engines Refill Capacities and Recommendations
C4.4 (Mech) Industrial Engine Engine Oil Cooler
C0.5, C0.7, C1.1, C1.5, C1.6 and C2.2 Industrial Engines Fuel Injection Timing - Check
Procedures for Diagnosis of Turbochargers{1052, 1052, 1053} Procedures for Diagnosis of Turbochargers{1052, 1052, 1053}
3500 Engines Engine Oil Lines
C1.1, C1.5 and C2.2 Engines for Caterpillar Built Machines Gear Group (Front) - Time
C1.1, C1.5 and C2.2 Engines for Caterpillar Built Machines Gear Group - Inspect
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.