- Machine Control & Guidance Products:
- ACCUGRADE (S/N: LGC1-UP)
- Track-Type Tractor:
- D6N LGP (S/N: GHS1-UP)
Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.
Problem
The AccuGrade Software Enabled Attachment (SEA) has been difficult to install on certain Track-Type Tractors. Some Electronic Control Modules (ECMs) do not automatically override the Temporary AccuGrade SEA installation status when the Permanent AccuGrade SEA is installed.
Solution
The machine ECM requires a valid Product ID. The Temporary AccuGrade SEA status must be manually set to "Not Installed" prior to requesting and entering the Factory Passwords for the Permanent AccuGrade SEA to be installed.
Cat Electronic Technician (ET) is required for this procedure. If you do not have Cat ET installed on your PC, obtain a current valid copy and install on your Personal Computer (PC).
AccuGrade SEA Installation Status Verification
- Ensure PC is connected to the machine through a communications adapter.
- Key the machine on.
- Open Cat ET.
Show/hide table
|
|
|
Illustration 1 | g02344957 |
- Cat ET will attempt to connect to components and Electronic Control Modules (ECMs) communicating on the data lines.
Show/hide table
|
|
|
Illustration 2 | g02344958 |
Show/hide table
|
|
|
Illustration 3 | g02344996 |
- A list of available ECMs will be displayed.
- If the Product ID has been entered into the ECM, select "Machine Control D6N" or appropriate machine-specific implement ECM and click on "OK" and skip to section: "Installation of Implement Control Software Enabled Attachments (SEA)".
- If the Product ID has not been entered, select "Machine Control Generic" ECM and click on "OK".
Show/hide table
|
|
|
Illustration 4 | g02345017 |
- Select "Machine Control Generic" ECM.
Show/hide table
|
|
|
Illustration 5 | g02345018 |
- "Machine Control Generic" will show as ECM selected.
Show/hide table
|
|
|
Illustration 6 | g02345036 |
- Select "Configuration Tool" icon.
Show/hide table
|
|
|
Illustration 7 | g02345037 |
- Select "Expand All" button at bottom of screen.
Show/hide table
|
|
|
Illustration 8 | g02345038 |
- Click on the Product ID cell for "Value". The row will highlight and the "Change" button will become available at the bottom of the screen. Select the "Change" button. The following box will pop up.
Show/hide table
|
|
|
Illustration 9 | g02345039 |
- Enter the serial number of the machine.
Show/hide table
|
|
|
Illustration 10 | g02345056 |
- Select the "OK" button. The following box will pop up.
Show/hide table
|
|
|
Illustration 11 | g02345058 |
- Select "Yes". The following box will pop up.
Show/hide table
|
|
|
Illustration 12 | g02345059 |
- Select "OK".
Note: If the below message is encountered, ensure that the ECM is updated to the most recent version of software available, and repeat the process for entering the Product ID. Cat ET will restart and reconnect to ECM.
Show/hide table
|
|
|
Illustration 13 | g02345060 |
Installation of Implement Control Software Enabled Attachments (SEA)
- If the Product ID is entered, continue process to select the ECM and install AccuGrade.
Show/hide table
|
|
|
Illustration 14 | g02346436 |
- Select "Machine Control D6N" or appropriate machine-specific implement ECM from menu on left side of screen.
Show/hide table
|
|
|
Illustration 15 | g02346479 |
- Select the "Configuration Tool" icon.
Show/hide table
|
|
|
Illustration 16 | g02346516 |
- Select the "Expand All" button on the bottom of the screen.
Show/hide table
|
|
|
Illustration 17 | g02346556 |
- Note the status of the following items in the "Machine Settings" section.
- "AccuGrade System Installation Status".
- "AccuGrade Temporary Installation Status".
- "AccuGrade Temporary Installation Time Remaining".
- In this case, the Permanent AccuGrade SEA or the Temporary AccuGrade SEA have not been installed, and the Temporary SEA will be disabled after the ECM has been set to "Installed" for 3000 minutes of service.
Installation of the AccuGrade Temporary SEA for 3000 Minutes of AccuGrade Free Use
Show/hide table
|
|
|
Illustration 18 | g02347838 |
Note: It may be necessary to request and enter Factory Passwords to change the status of the "AccuGrade Temporary Installation" SEA to "Installed" or "Not Installed" once the machine has accumulated over 50 hours of service.
Exercise caution when selecting the Machine Setting prior to making value changes. The Factory Password Request screens may look similar to one another.
Charges may occur from requesting Factory Passwords to change the permanent "AccuGrade System Installation Status" to "Installed".
- To install the "Temporary SEA" or "Temporary Installation", click the row for "AccuGrade Temporary Installation Status" and select the "Change" button at the bottom of the screen. The following box will pop up.
Show/hide table
|
|
|
Illustration 19 | g02347859 |
- "Installed" is the default value that is populated. when this window is opened, you may press "Cancel" to avoid installing the "AccuGrade Free Use" if desired.
- Select "Installed" from the drop-down list by using the arrow at the right side of the box.
Show/hide table
|
|
|
Illustration 20 | g02347860 |
- Select "OK".
Show/hide table
|
|
|
Illustration 21 | g02347861 |
- Select "Yes" to confirm that you want to change the installation status.
Show/hide table
|
|
|
Illustration 22 | g02347862 |
- The screen is updated with "AccuGrade Temporary Installation Status" as "Installed".
- AccuGrade is now installed for a limited time. The Temporary SEA will be disabled after the ECM has been set to "Installed" for 3000 minutes of service.
Note: It may be necessary to request and enter Factory Passwords to change the status of the "AccuGrade Temporary Installation" SEA to "Installed" or "Not Installed" once the machine has accumulated over 50 hours of service.
Exercise caution when selecting the Machine Setting prior to making value changes. The Factory Password Request screens for the temporary and permanent SEAs may look similar to one another.
Charges may occur from requesting Factory Passwords to change the permanent "AccuGrade System Installation Status" to "Installed".
Refer to Step 12 in ""Installation of the Permanent (Full) SEA for Unlimited AccuGrade Use"
" for obtaining and entering Factory Passwords.
Installation of the Permanent (Full) SEA for Unlimited AccuGrade Use
The "AccuGrade Temporary Installation Status" of "Installed" will prevent the Permanent "AccuGrade" SEA from being installed. Use the following procedure for installation of the Permanent SEA.
Show/hide table
|
|
|
Illustration 23 | g02347876 |
- Ensure that the "AccuGrade Temporary Installation Status" is "Not Installed".
- If "AccuGrade Temporary Installation Status" is "Installed", change to "Not Installed" by selecting the "AccuGrade Temporary Installation Status" row as shown above and select the "Change" button at the bottom of the screen.
Show/hide table
|
|
|
Illustration 24 | g02347877 |
- Select "Not Installed" from the drop-down list by using the arrow at the right side of the box.
- Select "OK".
Show/hide table
|
|
|
Illustration 25 | g02347896 |
- Select "Yes"
Show/hide table
|
|
|
Illustration 26 | g02347897 |
- Verify that the "AccuGrade Temporary Installation Status" value is "Not Installed".
Show/hide table
|
|
|
Illustration 27 | g02347916 |
- Click on the "AccuGrade System Installation Status" row to select it. Click on the "Change" button at the bottom of the screen. The following box will pop up.
Show/hide table
|
|
|
Illustration 28 | g02347918 |
- "Installed" is the default value populated.
- Select "Installed" from the drop-down list by using the arrow at the right side of the box.
Show/hide table
|
|
|
Illustration 29 | g02347919 |
- Select "OK".
Show/hide table
|
|
|
Illustration 30 | g02347920 |
- Select "Yes".
Show/hide table
|
|
|
Illustration 31 | g02347976 |
- Follow your procedure for obtaining SEA passwords. The "Save to File" button will save the necessary data for requesting the factory passwords to a file if communication is limited or not available at the location of the machine.
Note: Do not make any configuration changes until passwords are obtained and the rest of this procedure is complete.
Show/hide table
|
|
|
Illustration 32 | g02347978 |
- Enter Passwords upon receipt into the fields for Factory Password #1 and Factory Password #2 and select "OK".
Show/hide table
|
|
|
Illustration 33 | g02347982 |
- "AccuGrade System Installation Status" now shows "Installed".
Show/hide table
|
|
|
Illustration 34 | g02348035 |
- Disconnect ECM using "Disconnect" icon.
- Power down by turning off the machine key switch.
Show/hide table
|
|
|
Illustration 35 | g02347989 |
- If the machine is keyed off without disconnecting Cat ET, communication will be lost and the above screen will be displayed.
Confirm the Installation is Successful
- Ensure PC is connected to the machine through a communications adapter. Key the machine on.
Show/hide table
|
|
|
Illustration 36 | g02347997 |
- Select the "Connect" icon.
Show/hide table
|
|
|
Illustration 37 | g02347998 |
- Cat ET will detect and initialize ECM.
Show/hide table
|
|
|
Illustration 38 | g02348018 |
- Select "Machine Control D6N" or appropriate machine-specific implement ECM and click on "OK". The following screen will load.
Show/hide table
|
|
|
Illustration 39 | g02348019 |
- Select the "Configuration Tool" icon.
Show/hide table
|
|
|
Illustration 40 | g02348025 |
- Select the "Expand All" Button at the bottom of the screen.
Show/hide table
|
|
|
Illustration 41 | g02348026 |
- AccuGrade system installation status is "Installed".
- Once the Permanent SEA has been installed, the AccuGrade Temporary Installation Time Remining is set to "0 min", and AccuGrade Temporary Installation Status is set to "Unavailable".
- The AccuGrade SEA is now installed and available for use.
Show/hide table
|
|
|
Illustration 42 | g02348035 |
- Select the "Disconnect" icon at the top of the screen.
Show/hide table
|
|
|
Illustration 43 | g02348040 |
- Select the "Exit" icon at the top of the screen. The following box will pop up.
Show/hide table
|
|
|
Illustration 44 | g02348042 |
- Select "Yes" Cat ET will close.
Note: A machine solenoid and automatic valve calibration will need to be completed for proper AccuGrade operation and performance. Refer the appropriate instructions provided with the AccuGrade system for details regarding this procedure.