Speed Sensor (Transmission) - Remove
Removal Procedure
Note: Put identification marks on all hoses, on all hose assemblies, on all wires, and on all tube assemblies for installation purposes. Plug all hose assemblies and all tube assemblies. This helps to prevent fluid loss, and this helps to keep contaminants from entering the system.
Note: Cleanliness is an important factor. Before you begin the removal procedure, the exterior of the components should be thoroughly cleaned. This will help to prevent dirt from entering the internal mechanism.
Input Speed Sensor
- Disconnect harness assembly (1). Remove bolt (3) and speed sensor (2) .
Show/hide table
Illustration 1 | g01269299 |
Output Speed Sensors
- Disconnect harness assembly (2). Remove bolt (4) and speed sensor (1). Repeat for the remaining speed sensor (3) .
Show/hide table
Illustration 2 | g01269246 |
Caterpillar Information System:
C9 Marine Engines and C9 Marine Generator Sets Unit Injector Hydraulic Pump
3500C Marine Engines Turbocharger
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Bypass Static Switch (SMS Bypass Cabinet)
TA19-M2WD and TA19-M4WD Agricultural Transmissions Transmission - Disassemble
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Bypass Contactor and Capacitor
C13 and C15 On-Highway Engines Fuel System Secondary Filter - Replace
SPF343 and SPF343C Trailer Mounted Pumpers Emergency Stopping
3500B Industrial Engines with the ADEM 3 Electronic Control Module Starting Motor System
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Maintenance Bypass Disconnect Switch - SMS Bypass Cabinet
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Vibration Sensor - Calibrate
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Zig Zag Controller PWA (SMS Bypass Cabinet)
3600 Mechanical Unit Injector (MUI) to 3600 Electronic Unit Injector (EUI) Upgrade{1000, 1250} 3600 Mechanical Unit Injector (MUI) to 3600 Electronic Unit Injector (EUI) Upgrade{1000, 1250}
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Zig Zag Transformer (SMS Bypass Cabinet)
G3406 and G3412 Generator Sets Starting the Engine
TA22 Transmission Speed Sensor (Transmission) - Install
TA22 Transmission Relief Valve (Transmission Main) - Remove
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Vacuum Pump Oil - Change
TA22 Transmission Relief Valve (Transmission Main) - Install
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Zig Zag Contactor (SMS Bypass Cabinet)
TA22 Transmission Temperature Sensor (Transmission Oil) - Remove and Install
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Zig Zag Circuit Breaker (SMS Bypass Cabinet)
UPS 120, UPS 150, UPS 250, UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Zig Zag Overload Relay (SMS Bypass Cabinet)
C4.4 and C6.6 Industrial Engines and Engines for Caterpillar Built Machines E360 Low Engine Oil Pressure
C4.4 Industrial Engine Fuel Injection Timing - Check