- Normal Mode
- Service Mode
The operating modes allow you to perform various functions within the software. You select a mode when you turn on the display. The mode that is selected remains active until you turn off the display.
The AccuGrade system automatically operates in normal mode when you start the display. Turn the key start switch to ON and press the power key.
As a default, the following soft keys are available when the display is in normal mode.
- Select blade tip focus ("Blade: Left or Blade: Right")
- Set machine direction ("Direction: Forward")
- Set the horizontal offsets ("H. Offset.")
- Set the vertical offsets ("V. Offset.")
- Turn map recording on or off (if enabled)
- Set the GPS accuracy
You can also use the "Setup Menu – Configuration" dialog to perform the following when you are in Normal mode.
- Select Design
- Vertical Offset
- Horizontal Offset
- GPS Accuracy
- Edit the Blade Wear value
- Vertical Setup
- Set the Light Bar Scales and On-Grade Tolerance
- Display and Lightbar Brightness
- Calibrate Sensors
- Restore the Display Settings or the Machine Settings
- View basic Diagnostic information
Refer to the Operation and Maintenance Manual, SEBU8158 for more details on Normal mode operation.
Note: If you lack experience with the AccuGrade system, use extreme care when the display is in service mode. This ensures that you do not accidentally change the settings of the AccuGrade system.
Service mode allows the user access to all of the available options that the AccuGrade system offers.
Use service mode in order to change the settings that affect the operation of the AccuGrade system.
In order to turn on service mode, turn off the display if the display is ON. Press and hold down the "OK" key as you press the power key. Hold down the "OK" key until the display shows the start-up screen.
In order to turn off service mode, turn off the display.
Use the "Setup Menu - Configuration" dialog in order to perform the following when you are in service mode:
- Select Design
- Vertical Offset
- Horizontal Offset
- GPS Accuracy
- Blade Wear
- Lightbar Scales
- Display and Lightbar Brightness
- Calibrate Sensors
- Map recording
- Avoidance Zones
- Text items
- Display Direction
- Plan View Rotation
- Beeper Configuration
- Save Settings
- Restore Settings
- GPS Receiver Configuration
- Diagnostics
Use the "Setup Menu - Installation" dialog to perform the following when you are in Service Mode:
- Machine Settings
- Set Units
- Set Machine Dimensions
- Set the Radio Network
- Light Bar Connections
- Valve Calibration
- Wireless Communication Support
- Production Recording
- Upgrade Firmware
- Operator Configuration
- Software Option
- Enter Software Support Option
- Guidance Hours
- Select Language
Turn off the display in order to exit the service mode. This ensures that inexperienced users will not inadvertently change the settings of the AccuGrade system.