953C Track-Type Loader Caterpillar


Engine Starting with Jump Start Cables

Usage:

953C BBX

------ WARNING! ------

Batteries give off flammable fumes that can explode resulting in personal injury.

Prevent sparks near the batteries. They could cause vapors to explode. Do not allow the jump start cable ends to contact each other or the machine.

Do not smoke when checking battery electrolyte levels.

Electrolyte is an acid and can cause personal injury if it contacts skin or eyes.

Always wear eye protection when starting a machine with jump start cables.

Improper jump start procedures can cause an explosion resulting in personal injury.

Always connect the battery positive (+) to battery positive (+) and the battery negative (−) to battery negative (−).

Jump start only with an energy source with the same voltage as the stalled machine.

Turn off all lights and accessories on the stalled machine. Otherwise, they will operate when the energy source is connected.



NOTICE

When starting from another machine, make sure that the machines do not touch. This could prevent damage to engine bearings and electrical circuits.

Turn on (close) the battery disconnect switch prior to the boost connection to prevent damage to electrical components on the stalled machine.

Severely discharged maintenance free batteries do not fully recharge from the alternator after jump starting. The batteries must be charged to proper voltage with a battery charger. Many batteries thought to be unusable are still rechargeable.

This machine has a 24 volt starting system. Use only the same voltage for jump starting. Use of a welder or higher voltage damages the electrical system.

Refer to Special Instruction, Battery Test Procedure, SEHS7633, available from your Caterpillar dealer, for complete testing and charging information.


Use of Jump Start Cables

When the auxiliary starting receptacles are not available, use the following procedure.

  1. Determine the failure of the engine to start. Refer to Special Instruction, SEHS7768 on the use of 6V-2150 Starting/Charging Analyzer. Use this procedure if the machine does not have a diagnostic connector.

  2. Move the transmission control to the PARK position on the stalled machine. Lower all attachments to the ground. Move all controls to the HOLD position.

  3. Place the switch for the parking brake into the PARK position.

  4. On a stalled machine, turn the start switch key to the OFF position. Turn off the accessories.

  5. On a stalled machine, turn on the battery disconnect switch to the ON position.

  6. Move the machines together in order for the cables to reach. DO NOT ALLOW THE MACHINES TO CONTACT EACH OTHER.

  7. Stop the engine on the machine that is the electrical source. When you use an auxiliary power source, turn off the charging system.


    Illustration 1g00991871

  8. Check the battery caps for correct placement and for correct tightness. Make these checks on both machines. Make sure that the batteries in the stalled machine are not frozen. Check the batteries for low electrolyte.

  9. Connect the positive jump start cable to the positive cable terminal of the discharged battery.

    Do not allow positive cable clamps to contact any metal except for battery terminals.

  10. Batteries in series may be in separate compartments. Use the terminal that is connected to the starter solenoid.

  11. Connect the positive jump start cable to the positive terminal of the electrical source. Use the procedure from Step 9 in order to determine the correct terminal.

  12. Connect one end of the negative jump start cable to the negative terminal of the electrical source.

  13. Make the final connection. Connect the negative cable to the frame of the stalled machine. Make this connection away from the battery, the fuel, the hydraulic lines, or moving parts.

  14. Start the engine on the machine that is the electrical source. Also, you can energize the charging system on the auxiliary power source.

  15. Allow the electrical source to charge the batteries for two minutes.

  16. Attempt to start the stalled engine. Refer to Operation and Maintenance Manual, "Engine Starting". See the beginning of this topic.

  17. Immediately after the stalled engine starts, disconnect the jump start cables in reverse order.

  18. Conclude with a failure analysis on the starting charging system. Check the stalled machine, as required. Check the machine when the engine is running and the charging system is in operation.

Caterpillar Information System:

D6N Track-Type Tractor Power Train Axle - Remove and Install
D6N Track-Type Tractor Power Train Steering Differential and Brake - Assemble
966G Series II Wheel Loader and 972G Series II Wheel Loader Hydraulic System Hydraulic System Troubleshooting
3054E Industrial Engine Flywheel - Install
938G Wheel Loader and IT38G Integrated Toolcarrier Reference Material
938G Wheel Loader and IT38G Integrated Toolcarrier Seat
963C Track-Type Loader Power Train Transmission Stall - Test
AD45B Underground Articulated Truck Rollover Protective Structure (ROPS) - Inspect
AD30 Underground Articulated Truck Hydraulic System Oil Filter (Pilot) - Replace
AD30 Underground Articulated Truck Pressure Sensor (Transmission Oil) - Test - If Equipped
AD30 Underground Articulated Truck Radiator Core - Clean
AD30 Underground Articulated Truck Fuses - Replace
CAES Installation For Wheel Loader{7604} CAES Installation For Wheel Loader{7604}
CAES Installation For Wheel Tractor Scraper{7604} CAES Installation For Wheel Tractor Scraper{7604}
Rotating Group Adjustment Instructions for Bosch Rexroth Hydraulic Pumps and Motors {3203, 4351, 5058, 5070} Rotating Group Adjustment Instructions for Bosch Rexroth Hydraulic Pumps and Motors {3203, 4351, 5058, 5070}
953C Track-Type Loader Cooling System Extended Life Coolant - Change
966G Series II Wheel Loader and 972G Series II Wheel Loader Machine Systems Power Guard Actuator
953C Track-Type Loader Cooling System Water Temperature Regulator - Clean/Replace
966G Series II Wheel Loader and 972G Series II Wheel Loader Machine Systems Toggle Switch (Power Guard Actuator)
953C Track-Type Loader Engine Oil Sample - Obtain
AD30 Underground Articulated Truck Hydraulic System Oil Level - Check
AD30 Underground Articulated Truck Service Inspection
AD30 Underground Articulated Truck Hydraulic Tank Breaker Relief Valve - Clean
AD30 Underground Articulated Truck Indicators and Gauges - Test
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.