PL1000E Communication ECM Caterpillar


Electrical Connector - Inspect

Usage:

SR4B 1BN
ReferenceSpecial Instruction, SEHS9615, "Servicing DT Connectors".

ReferenceSpecial Instruction, REHS0148, "Listing Of Deutsch Connector Components"

ReferenceSpecial Instruction, SEHS9065, "Use Of CE Connector Tools".

ReferenceService Magazine, SEPD034227 January 97, "Field Repair Of Single Wire Breaks In Harnesses (Sealed Splice)".

ReferenceService Magazine, SEPD037128 July 97, "Protection Of Unsealed Electrical Terminations For Machines In Corrosive Applications".

ReferenceService Magazine, SEPD047324 May 99, "New DT Connector Plugs With Improved Seal Retention".

ReferenceService Magazine, SEPD054509 October 00, "Dielectric Grease Should Not Be Used In Electrical Connectors".

ReferencePocket Guide, SEBD0402, "Guidelines For Routing And Installing Wire Harness Assemblies".

Use this procedure under the following situation:

Use the following steps to help determine if the connector is the cause of the problem. If a problem is found in the electrical connector, repair the connector and verify that the problem has been corrected.

The following background information is related to this procedure:

Many of the operational procedures and the diagnostic code procedures in this troubleshooting guide will instruct to check a specific electrical connector.

Intermittent electrical problems are often caused by poor connections. Always check for an active diagnostic code before breaking any connections. Also, always check for an active diagnostic code after the connector is reconnected in order to verify that the problem disappears.

Simply disconnecting the connectors and then reconnecting the connectors can temporarily solve a problem at times. If this occurs, likely causes are loose terminals, bent terminals, improperly crimped terminals, corrosion, or harness routing that is improper.

The original source of the problem must then be identified in order to ensure that the problem does not reoccur.

Perform the following in order to thoroughly inspect the connectors and determine if the connectors are the cause of the problem.




Illustration 1g00820688

(1) Correctly Routed Harness

(2) Correctly Inserted Plug

(3) Incorrectly Routed Harness

(4) Incorrectly Inserted Plug




Illustration 2g00690571

Proper Installation of Plug




Illustration 3g00828600

DT Type sealing plug

The 8T-8729 Connector Pin (2) and the 8T-8730 Connector Socket (1) is designed to accept only one 16/18 AWG wire. Do not insert multiple wires of a smaller wire size. An incorrect method would be using two 24 AWG wires. The 9W-0852 Connector Pin and the 9W-0844 Connector Socket is designed to accept only one 14 AWG wire. Do not insert multiple wires of a smaller wire size. An example of an incorrect method is the use of two 20 AWG wires.

  1. CHECK THE CONNECTORS.

    1. Ensure that the connector is properly locked. Also, ensure that the two halves of the connector can not be pulled apart.

    1. Verify that the latch tab of the connector is properly latched. Verify that the latch tab of the connector is fully latched.

      Expected Result: The connector will securely lock. The connector and the locking mechanism are without cracks or breaks.

      Results:

      OK - The connector will securely lock. The connector and the locking mechanism are without cracks or breaks. Proceed to test step 2.

      NOT OK - A problem exists with the connector.

      Repair: Repair the connector or replace the connector, as required.

      STOP.

  1. CHECK THE ALLEN HEAD SCREW ON THE HARNESS CONNECTOR OF THE ECM.

    1. Ensure that the connector bolt is properly tightened. Be careful not to tighten the bolt too much. The bolt may break.

    1. Do not exceed 6.0 N·m (53.0 lb in) of torque on the connector bolt of the harness when the connector is being installed on the ECM.

      Expected Result: The harness connector is secure and the connector bolt of the ECM is properly torqued.

      Results:

      OK - The harness connector is secure and the connector is properly torqued. Proceed to test step 3.

      NOT OK - A problem exists with the connector.

      Repair: Secure the harness connector of the ECM. Ensure that the connector bolt is properly torqued.

      STOP.

  1. PERFORM A PULL TEST ON EACH CONNECTOR CONTACT.

    1. Each connector contact should withstand 45 N (10 lb) of pull. Each wire should remain in the connector body. This test checks whether the wire was properly crimped in the contact and whether the contact was properly inserted into the connector.

    1. The DT connectors use an orange wedge to lock the terminals in place.

    1. Check in order to ensure that the orange wedge is not missing and that the orange wedge is installed properly on the DT connectors.

      Note: A Crimp Tool should ALWAYS be used in order to crimp wires on connector contacts. Do not solder the terminals. Use the proper Crimp Tool.

      Expected Result: Each connector contact should withstand 45 N (10 lb) of pull. Each wire remains in the connector body.

      Results:

      OK - Each connector contact withstands 45 N (10 lb) of pull. Each wire remains in the connector body. Proceed to test step 4.

      NOT OK - A problem exists with the connector.

      Repair: Repair the wiring or replace the connector contact.

      STOP.

  1. CHECK THE WIRES FOR NICKS OR ABRASIONS IN THE INSULATION.

    1. Carefully inspect each wire for signs of abrasion, nicks, or cuts.

      The following areas are locations that should be checked:

      • Exposed insulation

      • Points of rubbing wire

    1. Check all of the hold down clamps for the harness in order to verify that the harness is properly clamped. Also check all of the hold down clamps for the harness in order to verify that the harness is not compressed by the clamp. Pull back the harness sleeves in order to check for a flattened portion of wire. The flattened portion of wire is caused by the clamp that holds the harness.

      Expected Result: The wires are free of abrasion, nicks, or cuts and the harness is properly clamped.

      Results:

      OK - The wires are free of abrasion, nicks, or cuts and the harness is properly clamped. Proceed to test step 5.

      NOT OK - A problem exists with the wiring.

      Repair: Repair the wires or replace the wires, as required.

      STOP.

  1. CHECK THE CONNECTORS FOR MOISTURE OR CORROSION.

    1. Ensure that the connector seals and the white sealing plugs are in place. If any of the seals or plugs are missing, replace the seal or plug. If necessary, replace the connector.

    1. Check all of the wiring harnesses in order to verify that the harness does not make a sharp bend out of a connector. This will deform the connector seal and this will create a path for the entrance of moisture. See Illustration 1.

      Note: It is normal to see some minor seal abrasion on the ECM connector seals. Minor seal abrasion will not allow the entry of moisture.

    1. Thoroughly inspect ECM connectors for evidence of moisture entry. If moisture or corrosion is evident in the connector, the source of the moisture entry must be found and the source of the moisture entry must be repaired. If the source of the moisture entry is not repaired, the problem will reoccur. Simply drying the connector will not fix the problem. Likely paths for the entrance of moisture are from missing seals, improperly installed seals, nicks in exposed insulation, and improperly mated connectors.

      Note: Moisture can also travel from one connector through the inside of a wire to the ECM Connector. If moisture is found in the ECM connector, thoroughly check all connectors and wires on the harness that connect to the ECM. The ECM is not the source of the moisture. Do not replace an ECM if moisture is found in either ECM connector.

      Note: If corrosion is evident on the contacts or the connector, use only denatured alcohol to remove the corrosion. Use a cotton swab or a soft brush to remove the corrosion. Do not use cleaners that contain trichloroethylene because trichloroethylene may damage the connector.

      Expected Result: All of the connectors should be completely coupled and all of the seals should be completely inserted. The harness and the wiring should be free of corrosion, moisture, abrasion or pinch points.

      Results:

      OK - All of the connectors are completely coupled and all of the seals are completely inserted. The harness and the wiring are free of corrosion, moisture, abrasions or pinch points. Proceed to test step 6.

      NOT OK - A problem exists with the connector, the wiring or the wiring harness. Moisture is present.

      Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled. Verify that the repair eliminates the problem by operating the engine for several minutes and by checking again for moisture.

      STOP.

  1. INSPECT THE CONNECTOR CONTACTS.

    1. Verify that the contacts are not damaged. Verify that the contacts are properly aligned in the connector and verify that the contacts are properly located in the connector.

      Expected Result: The contacts are properly aligned and the contacts appear undamaged.

      Results:

      OK - The contacts are properly aligned and the contacts appear undamaged. Proceed to test step 7.

      NOT OK - A problem exists with the connector contacts.

      Repair: Repair the contacts and wiring and/or replace the contacts and wiring.

      STOP.

  1. CHECK THE FIT OF THE CONTACTS.



      Illustration 4g00838765

      Retention of the Connector

      (1) Pin Contact

      (2) Socket Contact

      Note: This is especially important for intermittent problems.

    1. Use a new pin contact. Insert the pin contact into each socket contact one at a time in order to check for a good grip on the pin contact by the socket contact.

    1. Use a new socket contact. Insert the pin contact into each socket contact one at a time in order to check for a good grip on the pin contact by the socket contact. The pin contact are located on the mating side of the connector.

    1. The connector contact should stay connected when the connector is held in the position shown in Illustration 4. The connector contact is the pin contact or the socket contact.

      Expected Result: The pin contacts and the socket contacts appear to be OK.

      Results:

      OK - The pin contacts and the socket contacts appear to be OK. STOP.

      NOT OK - A problem exists with the connector terminal.

      Repair: Replace the connector contact.

      STOP.

Caterpillar Information System:

349F and 352F Excavators Swing Drive Oil - Change
C-10 Petroleum Engine Piston Cooling Jet
3508C, 3512C and 3516C Marine Engines Water Temperature Regulators - Install
3508C, 3512C and 3516C Marine Engines Water Temperature Regulators - Remove
GENSET, SR4, SR4 HV, SR4B and SR4B HV Electric Power Generation, 3126, 3176B, 3176C, 3196, 3408E, 3412C, 3412E, 3508, 3508B, 3512, 3512B, 3516, 3516B and G3616 Engines, 3406E GEN SET Generator Set, 3406E IND, 3408C IND and 3456 IND Industrial Engines J1939 Bridge
GENSET, SR4, SR4 HV, SR4B and SR4B HV Electric Power Generation, 3126, 3176B, 3176C, 3196, 3408E, 3412C, 3412E, 3508, 3508B, 3512, 3512B, 3516, 3516B and G3616 Engines, 3406E GEN SET Generator Set, 3406E IND, 3408C IND and 3456 IND Industrial Engines Diagnostic Capabilities
Installation Procedures for the 259-4020 Voltage Regulator Assembly (for use with Caterpillar Power Modules Equipped with Legacy Switchgear that Utilize the 131-5374 Annunciator Module Control Group ){4467} Installation Procedures for the 259-4020 Voltage Regulator Assembly (for use with Caterpillar Power Modules Equipped with Legacy Switchgear that Utilize the 131-5374 Annunciator Module Control Group ){4467}
GENSET, SR4, SR4 HV, SR4B and SR4B HV Electric Power Generation, 3126, 3176B, 3176C, 3196, 3408E, 3412C, 3412E, 3508, 3508B, 3512, 3512B, 3516, 3516B and G3616 Engines, 3406E GEN SET Generator Set, 3406E IND, 3408C IND and 3456 IND Industrial Engines Connector Locations
3508B, 3512B and 3516B Generator Set Engines Turbocharger - Install
C-10 Petroleum Engine Engine Oil Pan
C15 and C18 Engines for Caterpillar Built Machines Crankshaft - Install
C15 and C18 Engines for Caterpillar Built Machines Crankshaft - Remove
C-10 Petroleum Engine Housing (Front)
PL1000E Communication ECM Wiring Harness (Open Circuit) - Test
PL1000E Communication ECM Wiring Harness (Short Circuit) - Test
GENSET, SR4, SR4 HV, SR4B and SR4B HV Electric Power Generation, 3126, 3176B, 3176C, 3196, 3408E, 3412C, 3412E, 3508, 3508B, 3512, 3512B, 3516, 3516B and G3616 Engines, 3406E GEN SET Generator Set, 3406E IND, 3408C IND and 3456 IND Industrial Engines Electronic Control Module (ECM) - Flash Program
C15 and C18 Engines for Caterpillar Built Machines Electric Starting Motor - Remove and Install
GENSET, SR4, SR4 HV, SR4B and SR4B HV Electric Power Generation, 3126, 3176B, 3176C, 3196, 3408E, 3412C, 3412E, 3508, 3508B, 3512, 3512B, 3516, 3516B and G3616 Engines, 3406E GEN SET Generator Set, 3406E IND, 3408C IND and 3456 IND Industrial Engines Electronic Control Module (ECM) - Configure
GENSET, SR4, SR4 HV, SR4B and SR4B HV Electric Power Generation, 3126, 3176B, 3176C, 3196, 3408E, 3412C, 3412E, 3508, 3508B, 3512, 3512B, 3516, 3516B and G3616 Engines, 3406E GEN SET Generator Set, 3406E IND, 3408C IND and 3456 IND Industrial Engines Electronic Control Module (ECM) - Replace
3126B Petroleum Engine Can Not Reach Top Engine RPM
3412E Petroleum Engine Electronic Unit Injector - Test
3412E Petroleum Engine Electronic Unit Injector - Adjust
C-10 Petroleum Engine General Information
3500 Engines Turbocharger - Assemble - Type 2
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.