Illustration 1 | g01102584 |
Illustration 2 | g01102587 |
When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25 °C (77 °F)
- Speed ... 7643 ± 1683 rpm
- Current draw ... 67.5 ± 7.5 amp
- Voltage ... 23 V
- Current draw ... 67.5 ± 7.5 amp
(1) Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(2) Tighten the nut on the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(5) Tighten the nut on the motor terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 8 ± 3 N·m (71 ± 27 lb in)
9X-9511 Solenoid Assembly
Current consumption at 25 °C (77 °F)
- Pull in windings at 20V ... 56.5 ± 4.5 Amp
- Hold in windings at 20V ... 14.6 Amp