3176C and 3196 Engines for Caterpillar Built Machines Caterpillar


Water Temperature Regulator

Usage:

140H 126



Illustration 1g01399583

Typical example

Start to open temperature ... 87 to 90 °C (189 to 194 °F)

Fully open temperature ... 98 °C (208 °F)

(A) Minimum opening distance at 98 °C (208 °F) ... 10.4 mm (0.41 inch)

Maximum time from fully closed position at 85 °C (185 °F) to fully open position at 100 °C (212 °F) ... Three minutes

Maximum time from fully open position at 100 °C (212 °F) to fully closed position at 85 °C (185 °F) ... Six minutes