G3408 and G3412 Engines Caterpillar


Ignition Transformer

Usage:

G3412 3NK



Illustration 1g00745822

(1) Outlet

(2) Positive terminal

(3) Negative terminal

The resistance of the primary coil is measured between positive terminal (2) and negative terminal (3) of the transformer.
Primary coil resistance ... 0.3 to 0.5 ohms
The resistance of the secondary coil is measured between negative terminal (3) of the transformer and outlet (1) for the high current.
Secondary coil resistance ... 7,500 to 10,000 ohms

Caterpillar Information System: