Illustration 1 | g00286672 |
Illustration 2 | g00286673 |
207-1532 Electric Starting Motor Gp
When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25°C (77°F)
- Speed ... 6900 ± 1800 rpm
- Current draw ... 127.5 ± 27.5 amp
- Voltage ... 11 V
- Current draw ... 127.5 ± 27.5 amp
(1) Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(2) Tighten the nut on the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(5) Tighten the nut on the motor terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 8 ± 3 N·m (71 ± 27 lb in)
Illustration 3 | g00123515 |
147-8588 Electric Starting Motor Gp
When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25°C (77°F)
- Speed ... 6950 ± 1650 rpm
- Current draw ... 115 ± 25 amp
- Voltage ... 23 V
- Current draw ... 115 ± 25 amp
(1) Tighten the large nuts to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(2) Tighten the small nuts to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)