Customer parameters may be changed repeatedly as operational requirements change.
The following information is a brief description of the customer specified parameters. The following parameter values are included with the descriptions:
- Minimum
- Maximum
- Default
ECM Identification Parameter
Equipment ID
"Equipment ID" is the identification of the equipment that is assigned by the customer. The "Equipment ID" is only for reference by the customer. The "Equipment ID" is not required by the Electronic Control Module (ECM).
Value     | Default     |
---|---|
17 digits The available characters are dependent on the service tool that is being used.     |
Not programmed     |
Engine Configuration Parameters
Ether Solenoid Configuration
The ether solenoid configuration defines the presence of a solenoid for an ether starting aid. Customer passwords are required in order to change this parameter.
Value     | Default     |
---|---|
Not Installed Continuous Flow Solenoid     |
Not Installed     |
Engine Warmup Elevated Idle Feature Enable Status
The engine warmup elevated idle feature will cause the engine to have an elevated idle for a set period after the engine is started. This feature allows the engine to reach ideal operating temperature in a shorter period.
Value     | Default     |
Enabled Disabled     |
Enabled     |
Engine Warmup Elevated Idle Delay Time
Minimum     | Maximum     | Default     |
3 minutes     | 30 minutes     | 10 minutes     |
Low System Battery Voltage Elevated Idle
This feature is used to increase an excessively low battery voltage while the engine is at idle.
Value     | Default     |
Enabled Disabled     |
Enabled     |
Engine Idle Shutdown
The Engine Idle Shutdown parameters define the engine response when the keyswitch is turned to the OFF position.
Engine Idle Shutdown Minimum Ambient Air Temperature
Value     | Default     |
---|---|
0 to 29 Degrees C     | 0 Degrees C     |
Engine Idle Shutdown Maximum Ambient Air Temperature
Value     | Default     |
---|---|
30 to 100 Degrees C     | 30 Degrees C     |
Engine Idle Shutdown Enable Status
Value     | Default     |
---|---|
Enabled Disabled     |
Disabled     |
Engine Idle Shutdown Delay Time
Value     | Default     |
---|---|
1 to 60 minutes     | 5 minutes     |
Engine Idle Shutdown Ambient Temperature Override Enable Status
Value     | Default     |
---|---|
Enabled Disabled     |
Enabled     |
Delayed Engine Shutdown
If the delayed engine shutdown feature is enabled, the engine will continue to run for a set period after the keyswitch has been turned to the OFF position. This feature allows the engine to cool in a controlled manner.
Delayed Engine Shutdown Enable Status
Value     | Default     |
Enabled Disabled     |
Enabled     |
Delayed Engine Shutdown Maximum Time
Minimum     | Maximum     | Default     |
1 minute     | 10 minutes     | 5 minutes     |
Fan Control
Engine Fan Type Configuration
Value     | Default     |
Viscous Clutch Direct Drive Variable Pitch     |
Viscous Clutch     |
Engine Fan Cooling Map
Value     | Default     |
Standard High Ambient     |
Standard     |
Aftertreatment Configuration
ARD Auto Regeneration Enable Status
The "ARD Auto Regeneration Enable Status" parameter determines whether automatic ARD regeneration is enabled.
Value     | Default     |
---|---|
Disabled Enabled     |
Enabled     |
Key Off Regeneration Enable Status
If "Key Off Regeneration" is enabled. A regeneration of the DPF can be performed after the keyswitch has been turned to the OFF position and the key has been removed.
Value     | Default     |
Enabled Disabled     |
Enabled     |
Key Off Aftertreatment Regeneration Maximum Time
Minimum     | Maximum     | Default     |
5 minutes     | 25 minutes     | 15 minutes     |
Factory Installed Aftertreatment #1 Identification Number
Value     | Default     |
Programmed Not Programmed     |
Not Programmed     |
DPF #1 Soot Loading Sensing System Configuration Code
The "DPF 1 Soot Loading Sensing System Configuration Code" parameter determines the type of diesel particulate filter #1 soot loading sensing system. This parameter identifies orientation of soot sensor, and the geometry of the DPF.
Value     | Default     |
---|---|
20(Hex) to 7F(Hex)     | 0     |
High Soot Load Aftertreatment Protection
The "High Soot Load Aftertreatment Protection" parameter determines whether aftertreatment protection is enabled.
Value     | Default     |
---|---|
Disabled Enabled     |
Disabled     |
System Settings
System Operating Voltage Configuration
The System Operating Voltage Configuration parameter is the operating voltage for the engine electrical system.
Value     | Default     |
---|---|
12 VDC 24 VDC     |
24 VDC     |
Security Access Parameters
CAN Communication Protocol Write Security
The CAN Communication Protocol Write Security parameter control the security required for writing information through the CAN bus.
Value     | Default     |
---|---|
Seed and Key No Security     |
Seed and Key     |
CAN Communication Protocol Read Security
The CAN Communication Protocol Read Security parameter control the security required for reading information from the CAN bus.
Value     | Default     |
---|---|
Seed and Key No Security     |
Seed and Key     |