G3516B Engines Caterpillar


E026 High Inlet Air Temperature Shutdown

Usage:

G3516B 7EZ
Conditions Which Generate This Code:

The crank terminate relay is set and the engine has been running for at least 30 seconds. The inlet air temperature has exceeded the trip point and the delay time has expired. No other codes for the inlet air temperature are active.

System Response:

The fuel is shut off. The shutdown output is activated. The code is logged.

Possible Performance Effect:

The engine is shut down.

Troubleshooting:

Test Step 1.

Refer to Troubleshooting, "Inlet Air Temperature (High)".

Results:

  • OK - STOP
Back to top