The monitor displays the default screen when the start switch is turned to the ON position. The default screen contains three gauges: fuel level, hydraulic oil temperature and engine coolant temperature.
Use the following Illustration to operate the monitor.
Illustration 1 | g01197803 |
Monitor Panel (1) Up key (2) Right key (3) Home key (4) Main menu key (5) Left key (6) Down key (7) Cancel key (8) OK key |
Table 1 contains parameters for "TOOL#1" through "TOOL#5".
DISPLAY     | "TOOL #1"     | "TOOL #2"     | "TOOL #3"     | "TOOL #4"     | "TOOL #5"     | |
---|---|---|---|---|---|---|
"TOOL PROGRAM: GENERAL"     | ||||||
"NAME"     | 0     | 0     | 0     | 0     | 0     | |
"MAX DIAL"     | 10     | 10     | 10     | 10     | 10     | |
"MIN DIAL"     | 1     | 1     | 1     | 1     | 1     | |
"UNDERSPEED ENABLE"     | ENABLED     | ENABLED     | ENABLED     | ENABLED     | ENABLED     | |
"WARNING HYD TEMP"     | 80     | 80     | 80     | 80     | 80     | |
"COMBINER ENABLE"     | DISABLED     | ENABLED     | ENABLED     | ENABLED     | ENABLED     | |
"TOOL PROGRAM: ATTACHMENT #1 VALVE"     | ||||||
"A1 FLOW" Flow setting of the attachment valve A1     |
250     | 250     | 250     | 250     | 250     | |
"A1 MULTI ADD FLOW" Additional oil flow for the A1 circuit     |
0.0     | 0.0     | 0.0     | 0.0     | 0.0     | |
"A1 NOMINAL PRES" Normal working pressure for the A1 circuit     |
16000     | 16000     | 16000     | 16000     | 16000     |
To access the tool parameters, enter the service mode on the monitor.
- From the default screen, press the main menu key (4) .
- From the "MAIN MENU" screen, use the right key (2) to scroll through the menu options.
- When the "SERVICE" option is highlighted, press the OK key (8) .
- When "PASSWORD" screen appears, use the right key (2) and the left key (5) in order to scroll through the characters. When the desired character is highlighted, press the OK key (8) . Enter the password for service FFF2 in order to continue to the "SERVICE" screen.
- After the password has been entered the "SERVICE" screen should appear. Refer to Illustration 2.
Note: For more detailed steps with entering passwords or entering the service mode, refer to Troubleshooting, "Using Service Mode" for the Tool Control System.
Illustration 2 | g01215792 |
Illustration 2 is a typical example of the "SERVICE" screen. |
Refer to Testing and Adjusting, "Work Tool Parameter - Program" for the Tool Control System for instructions on navigating the menus on the display.
Blank Table for System 2
Record any changes to System 2 in Table 2.
DISPLAY     | "TOOL #1"     | "TOOL #2"     | "TOOL #3"     | "TOOL #4"     | "TOOL #5"     | |
---|---|---|---|---|---|---|
"TOOL PROGRAM: GENERAL"     | ||||||
"NAME"     |     |     |     |     |     | |
"MAX DIAL"     |     |     |     |     |     | |
"MIN DIAL"     |     |     |     |     |     | |
"UNDERSPEED ENABLE"     |     |     |     |     |     | |
"WARNING HYD TEMP"     |     |     |     |     |     | |
"COMBINER ENABLE"     |     |     |     |     |     | |
"TOOL PROGRAM: ATTACHMENT #1 VALVE"     | ||||||
"A1 FLOW"     |     |     |     |     |     | |
"A1 MULTI ADD FLOW"     |     |     |     |     |     | |
"A1 NOMINAL PRES"     |     |     |     |     |     |