3500 Generator Set Engines Caterpillar


Lubrication

Usage:

3508 1ZF
Always use an air line lubricator with the air starting motors that have vanes.

For temperatures above 0 °C (32 °F), use a SAE 10W nondetergent oil of high quality.

For temperatures below 0 °C (32 °F), use air tool oil.

To maintain the efficiency of the starting motor, flush the starting motor at regular intervals. Pour approximately 0.5 L (0.53 qt) of diesel fuel into the air inlet of the starting motor and operate the starting motor. This procedure will remove the dirt, the water and the mixture of oil from the vanes of the air starting motor.

Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.