Usage:
Fluid Spillage Containment
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to "Tools And Shop Products Guide", NENG2500 for tools and supplies suitable to collect and contain fluids in Caterpillar machines. Dispose fluids according to local regulations and mandates.
1. Disconnect fuel line (1) from the fuel filter base. Cap and plug all openings immediately.
2. Remove fuel filter (3) from fuel filter base (2) with Tool (A).
3. Remove two bolts and washers (4), fuel filter base (2) and gasket (5) from fuel injection pump housing (6).
NOTE: The following steps are for the installation of the fuel filter and base.
4. Put gasket (5) and fuel filter base (2) in position on fuel injection pump housing (6), and install bolts and washers (4) to hold them.
5. Use Tool (A) and install fuel filter (3).
6. Connect fuel line (1) to the fuel filter base.