Turbocharger Outlet Pressure Sensor - Remove and Install
Removal Procedure
Show/hide table
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
- Cut cable strap (2) and disconnect harness assembly (1) from the turbocharger outlet pressure sensor.
Show/hide table
Illustration 1 | g00632044 |
Typical example |
- Remove turbocharger outlet pressure sensor (3) from the cylinder head.
Installation Procedure
Show/hide table
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
- Install turbocharger outlet pressure sensor (3) in the cylinder head.
Show/hide table
Illustration 2 | g00632044 |
Typical example |
- Connect harness assembly (1) for the turbocharger outlet pressure sensor. Install cable strap (2) .
Caterpillar Information System:
Electronic Modular Control Panel II+ (EMCP II+) for EUI Engines No Engine Shutdown - Troubleshoot
C9 Engine For Caterpillar Built Machines Unit Injector - Remove
Electronic Modular Control Panel II+ (EMCP II+) for EUI Engines Engaged Starting Motor - Troubleshoot
3126 Truck Engine Military Engine Support (Front) - Remove and Install
C9 Engine For Caterpillar Built Machines Rocker Arm and Shaft - Install
C9 Engine For Caterpillar Built Machines Rocker Arm - Assemble
3618 Engine Barring Group - Remove and Install
Electronic Modular Control Panel II+ (EMCP II+) for EUI Engines Indicator for Overcrank - Troubleshoot
Electronic Modular Control Panel II+ (EMCP II+) for EUI Engines Indicator for Low Coolant Level - Troubleshoot
3054 and 3056 Industrial and Generator Set Engines Flywheel Housing
C9 Engine For Caterpillar Built Machines Rocker Arm - Disassemble
3054 and 3056 Industrial and Generator Set Engines Flywheel
Caterpillar Monitoring System for Electronic Modular Control Panel Tattletale Mode
Electronic Modular Control Panel II+ (EMCP II+) for EUI Engines Charging System - Test
3618 Engine Crankshaft Front Seal and Wear Sleeve - Remove
Electronic Modular Control Panel II+ (EMCP II+) for EUI Engines Erratic GSC Operation - Troubleshoot
Electronic Modular Control Panel II+ (EMCP II+) for EUI Engines Zero Display of Voltage or Current - Troubleshoot
G3304 and G3306 Engines Belt Tightener
3126 Truck Engine Military Injection Actuation Pressure Control Valve - Remove
SR4 and SR4B Generators and Control Panels Space Heater - Check
SR4 and SR4B Generators and Control Panels Stator Winding Temperature - Measure/Record
G3304 and G3306 Engines Governor Control
3612 and 3616 Engines Prelube Pump Motors
3126 Truck Engine Military Injection Actuation Pressure Control Valve - Install