Usage:
2N2384 12V (Delco-Remy Number 1115523)
Current pull in windings at 5 V ... 8.4 to 9.5 A
Current pull in windings at 10 to 12 V ... 16.8 to 22.8 A
Current hold in windings at 10 to 12 V ... 1 A
(1) Torque for terminal nuts ... 14 ± 3 lb. in.(1.6 ± 0.3 N·m)
(2) Distance between shaft and plate:*
5L8982 or 3N548 Shaft ... .70 in.(17.8 mm)
7L5189 Shaft ... 1.25 in.(31.75 mm)
(3) Distance of plunger travel (start with dimension of .44 in. (11.2 mm) at (4) ... .62 in.(15.7 mm)
*On engine a test can show need for more adjustment. Hold in test on engine must take less than 2 A.
2N2385 24V or 32V (Delco-Remy Number 1115524)
Current pull in windings at 9 V ... 5.5 to 6.3 A
Current pull in windings at 20 to 24 V ... 12.2 to 16.8 A
Current hold in windings at 20 to 24 V ... .45 A
(1) Torque for terminal nuts ... 14 ± 3 lb. in.(1.6 ± 0.3 N·m)
(2) Distance between shaft and plate:*
5L8982 or 3N548 Shaft ... .70 in.(17.8 mm)
7L5189 Shaft ... 1.25 in.(31.75 mm)
T625 Shaft ... 1.10 in.(27.94 mm)
(3) Distance of plunger travel [start with dimension of .44 in. (11.2 mm) at (4)] ... .62 in.(15.7 mm)
*On engine a test can show need for more adjustment. Hold in test on engine must take less than 2 A.