Diesel engine exhaust contains products of combustion which may cause personal injury. Always start and operate the engine in a well ventilated area, and, if in an enclosed area, vent the exhaust to the outside. |
Personal injury or death can result from sudden machine movement. Sudden movement of the machine can cause injury to persons on or near the machine. To prevent injury or death, make sure that the area around the machine is clear of personnel and obstructions before operating the machine. |
Personal injury can result from rotating and moving parts. Moving fan blades and moving parts will throw or cut any object or tool that falls or is pushed into them. Make sure no one is working on, underneath or close to an engine that is running. Make sure the area is free of personnel. |
Required Tools | |||
---|---|---|---|
Tool | Part Number | Description | Qty |
A | N/A | Lap Top Computer with Plus+1 Software | 1 |
B(1) | 317-7485 | Communication Adapter (3) | 1 |
C(1) | 457-6114 | Cable As (DATA LINK) | 1 |
E | 370-4617 | Cable As | 1 |
(1) | The (C), (C), and (D) tools are part of 466-6258 Communication Adapter Gp. |
Note: The machine is equipped with four propel motors. The propel motor on the right side of the rear drum is similar to the propel motor on the left side of the front drum. The propel motor on the left side of the rear drum is similar to the propel motor on the right side of the front drum. The following procedure illustrates the test on the rear propel motors. The same procedure can be used to test the front propel motors.
- Drive the machine to a smooth, horizontal surface.
Show/hide table
Illustration 1 g06144094 - Move propel lever (1) to the NEUTRAL position.
- Move parking brake switch (2) to the ON position.
- Place the engine in ECO mode or low idle.
- Select "Main Menu" (3) on the machine display.
- Select "Machine Setup" (4).
Show/hide table
Illustration 3 g06148261 - Select "Engine Spd Sw" (5).
Show/hide table
Illustration 4 g06148286 - Select "ECO" (6) or "Low" (7).
Show/hide tableIllustration 2 g06148038 Show/hide tableIllustration 5 g06144108 - Move engine start switch (8) to the OFF position.
Show/hide table
Illustration 6 g06144759 - Connect Tool (C) and Tool (D) to Tool (B). Connect Tool (C) to diagnostic connector (9). Connect Tool (D) to USB port on Tool (A).
- Move engine start switch (8) to the START position. Release the switch when the engine starts.
- Move parking brake switch (2) to the OFF position.
- Operate the hydraulic system until the oil temperature reaches the test temperature of
45 °C (113 °F) . - Place the engine in ECO mode or low idle.
- Move parking brake switch (2) to the OFF position.
Note: First time users need to perform the tasks in the Communication and Connections Wizard. This wizard allows the Windows® operating system to recognize the USB device. Follow the on-screen instructions.
- Launch the Plus+1TM program on the computer to calibrate the propel pump neutral threshold.
Show/hide table
Illustration 7 g06156787 - Click "Calibrations" icon (10).
- Check "Active Codes". Clear any open "Active Codes".
Show/hide table
Illustration 8 g06156796 - Click "Start" icon (11) for the proper pump and direction.
Show/hide table
Illustration 9 g06156800 - Read and understand the safety requirements outlined on the warning page. Click "OK" icon (12).
- Follow the steps on the Plus+1TM program to calibrate the propel pump neutral threshold.
- Move engine start switch (8) to the OFF position.
- Disconnect tooling from diagnostic port (9).