- Off-Highway Truck/Tractor:
- 777G (S/N: T5A1-UP; TNM1-UP; RDR1-UP; T4Y1-UP; GT71-UP)
- Quarry Truck:
- 773G (S/N: MWH1-UP; JWS1-UP; T5S1-UP; T5T1-UP)
- 775G (S/N: T5F1-UP; RFM1-UP; MJS1-UP; T5W1-UP)
The new special instructions contains information that is needed to install the cold-weather cover group onto certain Off-Highway Trucks. The cold-weather group will improve the machines performance while operating in cold climate.
For a complete list of material and the correct procedure that is needed in order to install the cold-weather cover group, refer to Special Instruction, REHS9320, "Procedure to Install the Cold Weather Cover Group onto Certain Tier IV 773G, 775G and 777G Off-Highway Trucks" or Special Instruction, REHS9329, "Procedure to Install the Cold Weather Cover Group onto Certain Tier II 773G, 775G and 777G Off-Highway Trucks". The special instructions can be found on the Caterpillar service information system (SIS) and through the normal literature distribution system at your local Cat dealer.
Operating Conditions
Operating Conditions for the use of the 449-0978 Cover Gp and the 449-8545 Cover Gp     | ||
Ambient Temperature     | Operating Machine     | Machine Extended Idle     |
−40° C (−40° F) and Below     |
Cover closed     | Cover closed     |
−40° C (−40° F) to 0° C (32° F)     |
Cover half open     | Cover closed     |
0° C (32° F) to 15° C (59° F)     |
Cover fully open     | Cover closed     |
15° C (59° F) and Above     |
Remove cover     | Remove cover     |
- When the machine is at extended idling over 5 minutes or machine is operating in a temperature of −40° C (−40° F) and below, close the cover group.
Illustration 1 | g03604000 |
View of the cover group closed 777G |
Illustration 2 | g03620577 |
View of the cover group closed 773G/775G |
- When operating the machine in temperatures between −40° C (−40° F) to 0° C (32° F) open half, top or bottom, of the cover group,
Illustration 3 | g03604096 |
View of the cover group half-way open 777G |
Illustration 4 | g03620604 |
View of the cover group half-way open 773G/775G |
- When operating the machine in temperatures between 0° C (32° F) to 15° C (59° F) fully open (top and bottom) of the cover group.
Illustration 5 | g03604176 |
View of the cover group fully opened 777G |
Illustration 6 | g03620618 |
View of the cover group fully opened 773G/775G |
- When operating the machine in temperature 15° C (59° F) and above, remove the cover group.
Illustration 7 | g03604198 |
View of the cover group removed 777G |
Illustration 8 | g03620641 |
View of the cover group removed 773G/775G |