Usage:
All Models of Gas and Diesel Engines
Warranty Category: M
NOTE: Manufacturer's one year warranty from date of purchase on all parts except for the 156-1061 Oxygen Sensor which has a two year warranty.
Features/Benefits (156-1060 only)
-
- * Used for fast, easy set-up and servicing of lean burn and stoichometric engines
- * Measures exhaust concentrations of oxygen (O2), carbon monozide (CO), low nitric oxide (NO), and nitric dioxide (NO2)
- * Used for fast, easy set-up and servicing of lean burn and stoichometric engines
Features/Benefits (156-1070 only)
-
- * Used for fast, easy set-up and servicing of lean burn, stoichometric, and diesel engines
- * Measures exhaust concentrations of oxygen (O2), carbon monoxide (CO), nitric oxide (NO), nitric dioxide (NO2), and combustibles (CxHx)
- * Used for fast, easy set-up and servicing of lean burn, stoichometric, and diesel engines
Features/Benefits (156-1060 or 156-1070)
-
- * Also measures exhaust and ambient temperatures, stack draft, and smoke test
- * Calculates carbon dioxide, excess air, efficiency, and losses
- * Display shows all parameters at once and has two levels of zoom
- * Housed in a durable aluminum reinforced case
- * Durable pistol grip probe (one foot in length)
- * Built-in thermal printer
- * Automatic water dump
- * Also measures exhaust and ambient temperatures, stack draft, and smoke test
Specifications/Technical Information
- Input - exhaust from engine under test
- 156-1067 length - 305 mm (12.0 in)
- 156-1068 length - 4572 cm (15 ft)
- Power cord length - 2438 cm (8 ft)
- 156-1067 length - 305 mm (12.0 in)
Measurement Range
- Oxygen (O2) - 0 to 21%
- Carbon monoxide (CO) low - 0 to 4000 ppm
- Carbon monoxide (CO) high - 0 to 40,000 ppm
- Nitric oxide (NO) - 0 to 4000 ppm
- Nitrogen dioxide (NO2) - 0 to 500 ppm
- Combustibles (CxHx) - 0 to 6%
- Ambient temperature - -17.8 to 121.1°C (0 to 250°F)
- Exhaust temperature - -17.8 to 982.2°C (0 to 1800°F)
- Stack draft - 0 to 40.00 inches H20
- Smoke test - 0 to 9 spot method
- Carbon monoxide (CO) low - 0 to 4000 ppm
Measurement Resolution
- Oxygen - 0.1%
- Carbon monoxide, low - 1 ppm
- Carbon monoxide, high - 5 ppm
- Nitric oxide - 1 ppm
- Nitrogen dioxide - 1 ppm
- Combustibles - 0.01%
- Ambient temperature - 0.6°C (1°F)
- Exhaust temperature - 1.7°C (1°F)
- Stack draft - 0.01 inch H20
- Carbon monoxide, low - 1 ppm
Measurement Accuracy
- Oxygen - ±2% of reading
- Carbon monoxide, low - ±4% of reading
- Carbon monoxide, high - ±4% of reading
- Nitric oxide - ±4% of reading
- Nitrogen dioxide - ±4% of reading
- Combustibles - ±4% of reading
- Ambient temperature - -16.1°C (3°F)
- Exhaust temperature - -16.1°C (3°F)
- Stack draft - 2% of reading
- Carbon monoxide, low - ±4% of reading
Sensor Life
- Oxygen - 2 years
- Carbon monoxide, low - 3 years1
- Carbon monoxide, high - 3 years1
- Nitric oxide - 3 years1
- Nitrogen dioxide - 3 years1
- Combustibles - 3 years
- Ambient temperature - 10 years
- Exhaust temperature - 10 years
- Stack draft - 10 years
- Carbon monoxide, low - 3 years1
1Depends on usage and gas concentration
Power
- Internal - sealed lead acid battery, 12VDC, 2.2 AH rechargeable
- External selected - 110/220 VAC, 50/60 Hz
- External converter - 12VDC, battery cables and cigarette lighter plug (available separately)
- External selected - 110/220 VAC, 50/60 Hz
Operating Temperatures
- Analyzer - 6.7 to 50.0°C (20 to 122°F)
- Probe - -17.8 to 982.2°C (0 to 1800°F)
- Storage temperature - -40.0 to 60.0°C (-40 to 140°F)
- Probe - -17.8 to 982.2°C (0 to 1800°F)
Measurements
- External dimensions - 48.3 x 40.6 x 16.5 cm (19 x 16 x 6.50 in)
- Weight - 12.71 kg (28 lbs)
Components included with 156-1060 or 156-1070 Analyzer Group, Emission
Not shown: