Usage:
6T8021 12V (Activated to Run)
6T8022 24V (Activated to Run)
6T8023 32V (Activated to Run)
9G8180 (Lisk Number W-1121-2) Used With Woodward PSG Governors
Voltage rating ... 24 or 32V
Coil resistance at 25°C (77°F) ... 3.3 to 4.1 ohms
Activate to ... shutoff
NOTICE |
---|
This solenoid must not be used in constant operation for more than 2.5 minutes or damage may result. |
(1) Torque for terminal nuts ... 1.23 to 1.92 N·m (11 to 17 lb.in.)
(2) Distance from end of solenoid to end of plunger ... 11.18 mm (.440 in.)
(3) Tighten locknut to a torque of ... 24 ± 7 N·m (18 ± 5 lb.ft.)
(4) Distance of plunger travel [start with dimension (2)] ... 15.75 mm (.620 in.)
(5) 5L8983 Spring:
Length under test force ... 31.75 mm (1.25 in.)
Test force ... 9 N (2 lb.)
Free length after test ... 57.15 mm (2.25 in.)
Outside diameter ... 44.45 mm (1.750 in.)
(5) 7N9845 Spring:
Length under test force ... 31.09 mm (1.22 in.)
Test force ... 16.68 ± 1.33 N (3.75 ± .30 lb.)
Free length after test ... 78.75 mm (3.10 in.)
Outside diameter ... 44.45 mm (1.750 in.)
(6) Distance from shaft shoulder to plunger plate ... 35.3 mm (1.39 in.)