PL61 Pipelayer and D6K Track-Type Tractor Caterpillar


MID 039 - CID 1705 - FMI 03

Usage:

D6K LGP DHA
Conditions Which Generate This Code:


Illustration 1g01327233

Schematic of the Right Drive Pump Forward Control Solenoid

This diagnostic code is associated with the implement pilot supply solenoid. The FMI 03 means that the ECM has detected that the voltage of the solenoid circuit is above normal or that the ECM has detected voltage in the circuit when no voltage should be present.

Conditions that could causes this diagnostic code to be activated are:

  • The energize circuit of the solenoid is shorted to another voltage source.

  • The ECM has failed. This is unlikely.

Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.

System Response:

A Level 2 warning will be generated. Functionality is lost in forward direction. Motion in reverse direction is allowed with level 3 active event.

Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT

  1. Turn the disconnect switch and the key start switch to the OFF position.

  1. Disconnect the machine harness connector from the solenoid. Disconnect the machine harness connectors J1 and J2 from the ECM.

  1. At the machine harness ECM connectors, measure the resistance from contact J1-51 (wire K947-YL) to all of the other contacts that are used in the J1 and J2 connectors for the ECM.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • YES - Each resistance measurement is greater than 5000 ohms. The resistance measurement does not indicate a short in the machine harness. Proceed to Test Step 2.

  • NO - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness.

    Repair: The short is between wire K947-YL and the circuit that has a low resistance measurement.For information on testing for short circuits and finding short circuits, refer to Testing and Adjusting, "Wiring Harness (Short Circuit) - Test". Repair the machine harness or replace machine harness.

    STOP

Test Step 2. CHECK THE OPERATION OF THE ECM

The disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.

  1. At the machine harness connector J1 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire K947-YL and socket at contact J1-51 from the harness connector.

  1. Reconnect the machine harness J1 and J2 connectors to the ECM.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Observe the status of the active CID 1705 FMI 03 diagnostic code.

Expected Result:

The CID 1705 FMI 03 diagnostic code is no longer active. A CID 1705 FMI 05 diagnostic code is now active.

Results:

  • YES - The CID 1705 FMI 03 diagnostic code is no longer active. A CID 1705 FMI 05 diagnostic code has been activated after the solenoid energize circuit was disconnected. The ECM has responded correctly to the open circuit condition in the solenoid circuit.

    Reinstall the disconnected solenoid energize wire back into the correct space in the ECM connector before proceeding to the next test step.

    Proceed to Test Step 3.

  • NO - The CID 1705 FMI 03 diagnostic code remains active. The status of the active diagnostic code did not change when the solenoid energize wire was disconnected from the ECM.

    Repair: The ECM has not responded correctly to the open condition in the solenoid circuit. The operation of the ECM is not correct.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

Test Step 3. CHECK THE STATUS OF THE DIAGNOSTIC CODE

  1. Inspect the harness connectors and clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.

  1. Reconnect all harness connectors. Make sure that the connectors are fully seated and the clips for each connector are completely fastened.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Determine if the CID 1705 FMI 03 diagnostic code is active.

Expected Result:

The CID CID 1705 FMI 03 diagnostic code is active.

Results:

  • YES - The CID 1705 FMI 03 diagnostic code remains active.

    Repair: Check the circuit again. Use the Caterpillar Electronic Technician (ET) service tool, if available, in order to perform a "Wiggle Test" on the machine wiring harness. The wiggle test can detect momentary or intermittent shorts or opens in the machine wiring harness.If the problem remains, the ECM may have failed. This is unlikely because the ECM detected the open circuit condition in the solenoid circuit and activated the FMI 05 diagnostic code when the solenoid energize wire was disconnected.Verify that all possible causes of the diagnostic code have been investigated. Exit this procedure and perform this procedure again.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the diagnostic code is not found and the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 1705 FMI 03 code is not active. The problem does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

2008/02/25 Improved Solenoid Valve Groups Are Available {5479}
AS3301C Asphalt Screed Sloper Jack - Remove
AS3301C Asphalt Screed Sloper Group - Install
AS3301C Asphalt Screed Sloper Group - Remove
2006/09/11 A New Thermostat for the Jacket Water Heater {1383}
793D Off-Highway Truck/Tractor Oil Screen (Front Brake Cooler) - Assemble
793D Off-Highway Truck/Tractor Oil Screen (Front Brake Cooler) - Disassemble
2006/10/02 An Improved Damper for the Suspension Seat Is Used {7312, 7324}
AS3301C Asphalt Screed Deflector Plates (Strike-Off) - Remove and Install
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Power Train Electronic Control System MID 027 - CID 2113 - FMI 04
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Power Train Electronic Control System MID 027 - CID 2113 - FMI 03
2006/09/25 An Update to the Spider Assembly Improves the Retention of the Stake Nut in the Differential Assembly {3258}
AS3301C Asphalt Screed Sloper Jack - Install
246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Systems Hydraulic Tank
AS3301C Asphalt Screed Hydraulic Cylinder (Extender Extend) - Remove and Install
D6K Track-Type Tractor Electrohydraulic Power Train Hydraulic Oil Cooler
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Power Train Electronic Control System MID 027 - CID 2199 - FMI 03
PL61 Pipelayer and D6K Track-Type Tractor MID 039 - CID 1705 - FMI 05
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Power Train Electronic Control System MID 027 - CID 2199 - FMI 04
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Power Train Electronic Control System MID 027 - CID 2199 - FMI 08
AS3251C Asphalt Paver Height Adjuster Group (Extender) - Remove
PL61 Pipelayer and D6K Track-Type Tractor MID 039 - CID 1705 - FMI 06
AS3251C Asphalt Paver Height Adjuster Group (Extender) - Install
24M Motor Grader Assembly Instruction {7000, 7960} 24M Motor Grader Assembly Instruction {7000, 7960}
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.