TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Caterpillar


Output Low IQAN XP2 A1-23

Usage:

TK711 101
Conditions Which Generate This Code:


Illustration 1g01296666

Connections for the tool up solenoid

This diagnostic code is associated with the solenoid valve. The "Output low" means that the module has determined that an open in the circuit exists.

The possible causes of this diagnostic code are listed below:

  • The energize circuit of the solenoid is open.

  • The return circuit of the solenoid is open.

  • The solenoid has failed.

  • The module has failed. This is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of "Output low" for pin 23 of the IQAN-XP2 A1 module is active before performing this procedure.

Note: Use a Digital Multimeter for the measurements in this procedure.

Test Step 1. CHECK THE SOLENOID.

  1. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.

  1. Disconnect the solenoid with the active diagnostic code from the machine harness.

  1. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire X790-GN) to contact 2 (wire X789-YL).

  1. Observe the status of the "Output low" diagnostic code.

Expected Result:

The diagnostic code is active. Then, the diagnostic code changes from "Output low" to "Output high" as the jumper wire is installed.

Results:

  • YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.

  • NO - The diagnostic is no longer active. The solenoid has failed.

    Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the problem.

    STOP

Test Step 2. CHECK THE HARNESS FOR AN OPEN.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  1. Disconnect the machine harness connector(s) from the module.

  1. The jumper wire that was installed in the previous Test Step remains in place.

  1. At the machine harness connector, measure the resistance from signal contact IQAN XP2 A1 - 23 (wire X790-GN) to contact IQAN XP2 A1 - 24 (wire X789-YL).

Expected Result:

The resistance is less than 5.0 ohms.

Results:

  • OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.

    Repair: Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.

  1. Inspect the harness connectors and clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.

  1. Reconnect all harness connectors making sure that the connectors are fully seated and the clips for each connector are completely fastened.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Check the status of the "Output low" diagnostic code for pin 23 of the IQAN-XP2 A1 module.

Expected Result:

The "Output low" diagnostic code for pin 23 of the IQAN-XP2 A1 module is active.

Results:

  • YES - The "Output low" diagnostic code for pin 23 of the IQAN-XP2 A1 module is active. The diagnostic code has not been corrected.

    Repair: It is unlikely that the module has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the module.

    STOP

  • NO - The "Output low" diagnostic code for pin 23 of the IQAN-XP2 A1 module is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

AccuGrade® - CD700 Grade Control System (GPS/ATS/Sonic/Cross Slope) Light Bar
AS2302 Screed Extender Carriage - Check and Adjust
2006/08/07 A New Flasher Assembly is Now Used {4493}
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output Low IQAN XP2 A1-25
12M Motor Grader Work Tool Lift - Lubricate
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output Low IQAN XP2 A1-31
AccuGrade® - CD700 Grade Control System (GPS/ATS/Sonic/Cross Slope) Text View
AccuGrade® - CD700 Grade Control System (GPS/ATS/Sonic/Cross Slope) Profile View
572R Series II Pipelayer Brakes, Indicators and Gauges - Test
Field Installation of the 785C Off-Highway Truck Air Intake Update{1051, 1054, 1071} Field Installation of the 785C Off-Highway Truck Air Intake Update{1051, 1054, 1071}
D6K Track-Type Tractor Radiator Core - Clean
572R Series II Pipelayer Boom Pivot Pins - Lubricate
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output Low IQAN XP2 A1-19
572R Series II Pipelayer Engine Oil Level - Check
Cab Display Error Recovery Procedure For VIMS Software {7601, 7620} Cab Display Error Recovery Procedure For VIMS Software {7601, 7620}
14L Motor Grader Braking and Hydraulic Fan System Pressure Sensor (Hydraulic Fan)
2006/08/21 Improved Radiator Fill Door {7155}
770, 772, 773F and 777F Off-Highway Truck/Tractors and 775F Quarry Truck Monitoring System Warning Operation
572R Series II Pipelayer Fairlead Sheave - Lubricate
770, 772, 773F and 777F Off-Highway Truck/Tractors and 775F Quarry Truck Monitoring System General Information
C7 Engines for Caterpillar Built Machines Crankshaft
14M Motor Grader Circle Drive Oil - Change
C15 and C18 Petrolem Generator Set Engines ECM Software - Install
16M Motor Grader Circle Top - Lubricate
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.