Usage:
127-2150 (12V), 127-2151 (12V)
Current consumption (draw) both windings at 8.6V ... 2.35 ± 0.15A
(1) Torque for large terminal nuts ... 3.6 ± 0.4 N·m (32 ± 4 lb in)
127-2142 (24V), 127-2145 (24V)
Current consumption (draw) hold-in windings at 17V ... 0.82 ± 0.06A
(1) Torque for large terminal nuts ... 3.6 ± 0.4 N·m (32 ± 4 lb in)
Current consumption (draw) at 25°C (77°F)
127-2142 ... 0.82 ± 0.06 A at 17 V
127-2145 ... 1.35 ± 0.1 A at 14.4 V
(1) Torque for large terminal nuts ... 3.2 to 4.0 N·m (30 to 35 lb in)
Tighten small coil nuts to a torque of ... 1.70 ± .25 N·m (15 ± 2 lb in)
Typical Illustration
(1) Torque for large terminal nuts ... 4.0 ± 0.5 N·m (35 ± 4 lb in)
Coil voltage ... 24 V
Current Consumption (draw) at 16.0 V ... 0.58 ± 0.6 A
NOTE: In starting applications the switch should be mounted with terminal ends down to avoid accidental shorting across terminals. In applications where accidental shorting across terminals does not pose a hazard, mount switch with terminal end pointing up to enhance sealing.