Usage:
5L7442 Sending Unit
Resistance at:
93°C (200°F) ... 800 to 900 ohms
5L7443 Sending Unit
Resistance at:
38°C (100°F) ... 403 to 493 ohms
71°C (160°F) ... 118 to 138 ohms
104°C (220°F) ... 44 to 49 ohms
6N5926 (24V)
Inspection procedure: The resistance of sender must fall within the limits shown in chart at indicated bath temperature with sender in a continuous flow bath with series resistance and applied voltage specified in chart. Bath medium shall be U con oil spec. 50-HB-280X with flow controlled to 228.6 to 254.0 mm per second. Power shall be applied for a minimum of seven minutes before inspection.
Oil Pressure Sender
NOTE: Tap sender when checking calibration. Readings should be taken on decreasing pressure.
Typical Illustration
5L7450 Sending Unit
Resistance at:
0 kPa (0 psi) ... 0 ohms
140 kPa (20 psi) ... 13.5 ohms
550 kPa (80 psi) ... 30 ohms
5L7449 Sending Unit
Resistance at:
0 kPa (0 psi) ... 0 to 1 ohm
415 kPa (60 psi) ... 4.5 to 6.5 ohms
2050 kPa (300 psi) ... 28 to 31 ohms
302010 Sending Unit
Resistance at:
0 kPa (0 psi) ... 0 to 3.0 ohms
70 kPa (10 psi) ... 5 to 16 ohms
550 kPa (80 psi) ... 90 ohms
7W2118 Sending Unit
Resistance at:
0 kPa (0 psi) ... 0 to 4.0 ohms
276 kPa (40 psi) ... 7 to 11 ohms
2068 kPa (328 psi) ... 69.5 to 75.5 ohms.
9X1124 Sending Unit
Resistance at:
0 kPa (0 psi) ... 227 to 257 ohms
138 kPa (20 psi) ... 142.0 to 162.5 ohms
552 kPa (80 psi) ... 21.5 to 49.5 ohms