Usage:
When installing switch, tighten to a maximum of ... 40 ± 5 N·m (30 ± 4 lb ft)
Terminal No. 1 is common.
Terminal No. 2 is normally open.
Terminal No. 3 is normally closed.
6T1546, 9X4276
With pressure increase, terminal 2 closes and terminal 3 opens at ... 93 ± 21 kPa (14 ± 3 psi)
With pressure decrease, terminal 2 opens and terminal 3 closes at ... 69 ± 21 kPa (10 ± 3 psi)
6T6652
With pressure increase, terminal 2 closes and terminal 3 opens at ... 158 ± 28 kPa (23 ± 4 psi)
With pressure decrease, terminal 2 opens and terminal 3 closes at ... 124 ± 21 kPa (18 ± 3 psi)
122-1522
With pressure increase, terminal 2 closes and terminal 3 opens at ... 76 ± 20 kPa (11 ± 3 psi)
With pressure decrease, terminal 2 opens and terminal 3 closes at ... 52 ± 17 kPa (8 ± 3 psi)
When installing switch, tighten to a of ... 30 ± 3 N·m (22 ± 2 lb ft)
2L3402
With pressure increase the switch closes ... 24.0 ± 3.5 kPa (3.5 ± .5 psi)
With pressure increase the switch closes ... 20 kPa (3 psi)
3L6306
With pressure increase the switch closes ... 55 ± 15 kPa (8 ± 2 psi)
With pressure increase the switch closes ... 42 kPa (6 psi)
7N5946
With pressure increase the switch closes ... 145 kPa (21 psi)
With pressure increase the switch closes ... 75 ± 20 kPa (11 ± 3 psi)
2N7744
With pressure increase the switch closes ... 44 ± 19 kPa (6 ± 3 psi)
With pressure increase the switch closes ... 27 ± 23 kPa (4 ± 3 psi)
9G8010
With an increase in pressure, switch closes at ... 90 ± 25 kPa (13 ± 4 psi)
With a decrease in pressure, switch opens at ... 70 ± 25 kPa (10 ± 4 psi)
3N7443
With an increase of pressure, switch operates at ... 130 to 145 kPa (19 to 21 psi)
With a decrease of pressure, switch operates at ... 105 to 110 kPa (15 to 16 psi)
Temperature Switch Assembly
3N7442
Switch must open between ... 24 and 29°C (75 and 84°F)
Switch must close between ... 18 and 24°C (64 and 75°F)
6N5899
Switch must open between ... 35 and 41°C (95 and 105°F)
Switch must close at minimum ... 27°C (81°F)
Torque terminal screws to a maximum of ... 1.2 N·m (11 lb in)
5N8597
Switch operates when the temperature increases to ... 97 to 99°C (207 to 210°F)
When installing switch tighten to a torque of ... 52 ± 8 N·m (38 ± 6 lb ft)
Terminal A is normally open.
Terminal B is common.
Terminal C is normally closed.
2W8916
With an increase of temperature, switch must close between ... 91 and 93°C (196 and 199°F)
With a decrease of temperature, switch must open at a minimum of ... 85°C (185°F)
5N8857
With an increase of temperature, switch must close between ... 97 and 99°C (207 and 210°F)
With a decrease of temperature, switch must open at a minimum of ... 91°C (196°F)