Removal Procedure
Show/hide table
Table 1
Required Tools     |
Tool     |
Part Number     |
Part Description     |
Qty     |
ZZ     |
6V-9508     |
Face Seal Plug (11/16 - 16 THD)     |
1     |
6V-9829 |
Cap Assembly (11/16 - 16 THD)     |
1     |
6V-9511 |
Face Seal Plug (1 3/16 - 12 THD)     |
2     |
6V-9832 |
Cap Assembly (1 3/16 - 12 THD)     |
2     |
Note: SERVICE DATA: TOOLING (ZZ) WILL NOT BE IDENTIFIED IN PHOTOGRAPHS IN THE REMOVAL OR THE INSTALLATION. THIS TOOLING IS SHOWN IN ORDER TO ASSIST THE EXPERIENCED SERVICEMAN.
Note: Put identification marks on all hoses, on all hose assemblies, on all wires, and on all tube assemblies for installation purposes. Plug all hose assemblies and all tube assemblies. This helps to prevent fluid loss, and this helps to keep contaminants from entering the system.
Show/hide table
|
NOTICE |
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
|
Show/hide table
|
Personal injury can result from hydraulic oil pressure and hot oil. Hydraulic oil pressure can remain in the hydraulic system after the engine has been stopped. Serious injury can be caused if this pressure is not released before any service is done on the hydraulic system. Make sure all of the work tools have been lowered to the ground, and the oil is cool before removing any components or lines. Remove the oil filler cap only when the engine is stopped, and the filler cap is cool enough to touch with your bare hand. |
|
Show/hide table
|
|
|
Illustration 1 | g01133777 |
- Disconnect harness assembly (3) .
- Remove bolts (1) and support (2) .
Show/hide table
|
|
|
Illustration 2 | g01133754 |
- Disconnect hose assemblies (5) from piston motor (4) .
Show/hide table
|
|
|
Illustration 3 | g01133762 |
- Remove hose clamp (6). Move hose assemblies (5) out of the way.
Show/hide table
|
|
|
Illustration 4 | g01133763 |
- Remove bolts (8) and cover (7) .
Show/hide table
|
|
|
Illustration 5 | g01133764 |
- Remove bolts (8) and plate (9) .
Show/hide table
|
|
|
Illustration 6 | g01133802 |
- Disconnect all necessary harness assemblies (10). Remove the locknut and cables (11) .
- Replace the covers for protection.
Show/hide table
|
|
|
Illustration 7 | g01133806 |
- Remove ground cable (12) .
Show/hide table
|
|
|
Illustration 8 | g01133807 |
- Remove bolts (14) and cover (13) .
Show/hide table
|
|
|
Illustration 9 | g01133842 |
Show/hide table
|
|
|
Illustration 10 | g01133844 |
- Attach a suitable lifting device on hydraulic generator (15). The weight of hydraulic generator (15) and piston motor (4) is approximately 155 kg (341 lb).
- Remove bolts (16) and hydraulic generator (15) .