Usage:
Start By:
a. remove fuel filter
FLUID SPILLAGE CONTAINMENT
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to "TOOLS AND SHOP PRODUCT GUIDE, NENG2500", for tools and supplies suitable to collect and contain fluids in Caterpillar machines. Dispose fluids according to local regulations and mandates.
1. Turn the fuel supply valve to the "OFF" position.
2. Remove two bolts (2). Remove fuel priming pump (1) and the gasket.
3. Mark two hoses (3) for identification. Disconnect two hoses (3) from filter base (5). Cap and plug all openings immediately.
4. Remove two bolts and nuts (4) from the filter base. Remove filter base (5).
NOTE: For installation of the fuel priming pump and filter base, reverse the removal steps.
End By:
a: install fuel filter