Usage:
1. Remove cover assembly (1) and door assembly (2) from the generator.
2. Remove the terminal marker from the regulator terminal strip.
3. Put identification marks on wires (3) for correct installation and disconnect wires (3) from the regulator terminal strip.
4. Remove screws (6) and the washers to remove regulator assembly (5) and bracket assembly (4) as a unit from the generator.
5. Remove bolts (7) and the washers to remove bracket assembly (4) from regulator assembly (5).
Install Regulator Assembly
1. Put bracket assembly (1) in position on regulator assembly (2) and install bolts (3) and the washers to hold the bracket assembly.
2. Put regulator assembly (2) and bracket assembly (1) as a unit in position on shock mounts (4) and install the screws and the washers to hold these in position.
3. Connect wires (5) to the regulator terminal strip.
4. Install the terminal marker on the regulator terminal strip.
5. Install door assembly (7) and cover assembly (6) on the generator.