Illustration 1 | g06096076 |
The battery disconnect switch is located on the left side of the machine on the rear bumper.
Disconnect Switch ON - To activate the electrical system, remove the padlock (if installed) from the battery disconnect switch and turn the switch lever clockwise. The battery disconnect switch must be turned to the ON position before you start the engine. |
Disconnect Switch OFF - To deactivate the electrical system, turn the battery disconnect switch counterclockwise to the OFF position. Secure the battery disconnect switch in the OFF position by installing a padlock through the holes on the switch lever and the locking plate. |
Note: The machine is designed so that the status of the battery disconnect switch position can be viewed from the ground level.
The battery disconnect switch and the engine start switch perform different functions. Turn off the battery disconnect switch in order to disable the entire electrical system. The battery remains connected to the electrical system when you turn off the engine start switch.
Turn the battery disconnect switch to the OFF position and secure with a padlock when you service the electrical system or any other machine components.
Also turn the battery disconnect switch to the OFF position and secure with a padlock when the machine will not be used for an extended period of a month or more. This action will prevent drainage of the battery.
NOTICE |
---|
Never move the battery disconnect switch to the OFF position while the engine is operating. Serious damage to the electrical system could result. |
To ensure that no damage to the engine occurs, verify that the engine is fully operational before cranking the engine. Do not crank an engine that is not fully operational.
Perform the following procedure in order to check the battery disconnect switch for proper operation:
- With the battery disconnect switch in the ON position, verify that electrical components in the operator compartment are functioning. Verify that the hour meter is displaying information. Verify that the engine will crank.
- Turn the battery disconnect switch to the OFF position.
- Verify that the following items are not functioning: electrical components in the operator compartment, hour meter and engine cranking. If any of the items continue to function with the battery disconnect switch in the OFF position, consult your Caterpillar dealer.