CID 0823 FMI 05 Lamp (Service) Current Below Normal - Test
Show/hide table
Illustration 1 | g00507787 |
Schematic of the VIMS service indicator lamp |
This diagnostic code is recorded when the VIMS module reads the current of the service indicator lamp circuit (wire E709-WH(White)) and the current is below normal. The service indicator lamp will not light if this diagnostic code is present.
- CHECK THE LAMP.
- At the service indicator lamp, use a jumper to connect wire E709-WH(White) to frame ground.
Expected Result: The diagnostic code CID 0823 FMI 05 is still active.
Results:
- OK - This diagnostic code remains active. The service indicator lamp is not causing the fault. Proceed to 2.
- NOT OK - This diagnostic code is not present. The lamp or the lamp socket is open. Replace the service indicator lamp. For the purposes of this procedure, the correct resistance for a lamp is less than 200 ohms. STOP.
- At the service indicator lamp, use a jumper to connect wire E709-WH(White) to frame ground.
- CHECK THE HARNESS.
- Turn the key start switch and the disconnect switch to the OFF position.
- Remove the jumper wire between wire E709-WH(White) and frame ground. Verify that the service indicator lamp is connected to the machine harness.
- Disconnect the machine harness from the VIMS main module.
- At the machine harness connector for the VIMS main module, measure the resistance between contact 21 (wire E709-WH(White)) and frame ground.
Expected Result: The resistance is greater than 100 ohms.
Results:
- OK - Resistance is greater than 100 ohms. The harness circuit is open. Proceed to 3.
- NOT OK - Resistance is less than 100 ohms. The harness circuit resistance is correct. Replace the VIMS main module. Refer to the Testing and Adjusting, "Module - Replace"section. STOP.
- CHECK THE HARNESS.
- Disconnect the signal wire (E709-WH(White)) from the service lamp socket.
- Measure the resistance between contact 21 of the VIMS main module harness connector and the lamp socket.
- Measure the resistance between the lamp socket and the frame ground.
Expected Result: The resistance is less than 5 ohms.
Results:
- OK - Resistance is less than 5 ohms. The circuit is correct. The failure is intermittent. Check all harness connections. STOP.
- NOT OK - Resistance is greater than 5 ohms. The circuit is NOT correct. Repair the machine harness or replace the machine harness. STOP.
Caterpillar Information System:
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0823 FMI 03 Lamp (Service) Voltage Above Normal - Test
Challenger 35, Challenger 45 and Challenger 55 Agricultural Tractors Implement, Steering and Brake Hydraulic Systems Steering Hydraulic System Operation
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0803 FMI 09 Interface Module (No. 3) Abnormal Update - Test
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0802 FMI 09 Interface Module (No. 2) Abnormal Update - Test
836G Landfill Compactor and 834G Wheel Dozer Window Washer Reservoir - Fill
3408E and 3412E Engines for Caterpillar Built Machines Pistons and Connecting Rods - Remove
3406C Engines for Caterpillar Built Machines Camshaft Bearings
IT14G Integrated Toolcarrier and 914G Wheel Loader Engine Supplement Air Inlet Heater - Remove and Install
IT14G Integrated Toolcarrier and 914G Wheel Loader Engine Supplement Refrigerant Compressor - Remove and Install
IT14G Integrated Toolcarrier and 914G Wheel Loader Engine Supplement Pump Mounting - Remove and Install
C-10 and C-12 Industrial Engines Fuel Pressure Sensor
IT14G Integrated Toolcarrier and 914G Wheel Loader Engine Supplement Refrigerant Condenser Fans and Motor - Remove and Install
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0823 FMI 06 Lamp (Service) Current Above Normal - Test
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0809 FMI 02 Speedometer/Tachometer Module (No. 1) Incorrect Signal - Test
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0809 FMI 12 Speedometer/Tachometer Module (No. 1) Failed - Test
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0810 FMI 02 Speedometer/Tachometer Module (No. 2) Incorrect Signal - Test
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0810 FMI 12 Speedometer/Tachometer Module (No. 2) Failed - Test
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0811 FMI 02 Quad Gauge Module (No. 1) Incorrect Signal - Test
836G Landfill Compactor and 834G Wheel Dozer Window Wiper - Inspect/Replace
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0811 FMI 12 Quad Gauge Module (No. 1) Failed - Test
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0812 FMI 02 Quad Gauge Module (No. 2) Incorrect Signal - Test
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0812 FMI 12 Quad Gauge Module (No. 2) Failed - Test
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0813 FMI 02 Quad Gauge Module (No. 3) Incorrect Signal - Test
5130, 5130B and 5230 Excavators, 784B, 785B, 785C, 789B, 789C, 793B and 793C Off-Highway Truck/Tractors and 992G, 994 and 994D Wheel Loaders Vital Information Management System (VIMS) CID 0813 FMI 12 Quad Gauge Module (No. 3) Failed - Test