797 5YW
Conditions Which Generate This Code:


Illustration 1g00875930

This diagnostic code is recorded when the transmission ECM has dropped off the CAT data link 10 times within a ten minute period for more than five seconds. The event is active until communication is reliable for more than ten minutes.

System Response:

This failure results in events that are logged against an ECM that can not be explained. The brake/cooling ECM can not communicate with this ECM or the ECM appears to work intermittently.

Test Step 1. VERIFY THE HARDWARE AND THE SOFTWARE PART NUMBERS.

  1. Verify whether the following part numbers are correct.

    • Software part number for the brake/cooling ECM

    • Software part number for the monitoring system

Expected Result:

Consult the Business Unit that is producing the product for the correct configuration for the machine.

Results:

  • OK - All part numbers are correct. Proceed to Test Step 2.

  • NOT OK - All of the part number are NOT correct.

    Repair: One of the following modules may have the wrong part number and/or the software configuration is NOT correct. See Testing and Adjusting, "Electronic Control Module (ECM) - Flash Program".

    Stop.

Test Step 2. INSPECT THE HARNESS CONNECTIONS.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  1. Inspect the harness connections that are related to the CAT data link. Make sure that the connectors are clean and tight.

  1. Check the mating of the connector.

  1. Check the wires at the connector.

  1. Check each wire for nicks and/or signs of abrasion in the insulation.

  1. Check for moisture at the connector.

  1. Check for dirty contacts and/or corroded contacts.

  1. Check each pin and check each socket.

Expected Result:

The machine harness connectors are tight and free of corrosion.

Results:

  • OK - The machine harness connectors are tight and the connectors are free of corrosion. Proceed to Test Step 3.

  • NOT OK - The machine harness connectors require repair.

    Repair: Repair the harness or replace the harness.

    Stop.

Test Step 3. CHECK FOR ADDITIONAL RELATED DIAGNOSTIC CODES.

  1. Ensure that all electronic control modules that use the CAT data link are connected.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Acknowledge any diagnostic codes that are currently displayed on the message center.

  1. Verify that NO related diagnostic codes are present.

Expected Result:

NO other diagnostic codes are present.

Results:

  • OK - NO other related diagnostic codes are present. Proceed to Test Step 4.

  • NOT OK - Other related diagnostic codes are present.

    Repair: Exit this procedure and perform the other related diagnostic codes. Verify that the other related diagnostic codes are NOT present. Observe the status of the CID 0296 FMI 02. If the CID 0296 FMI 02 remains, perform the diagnostic code procedure again.

    Stop.

Test Step 4. CHECK FOR AN OPEN HARNESS.

  1. The disconnect switch remains in the OFF position.

  1. All related electronic control modules remain disconnected from the machine harness.

  1. Check the continuity of the data link circuit in the machine harness.

  1. Perform the following measurements:

    Table 1
    Module     Contact     Wire    
    Transmission ECM     J1-7     892-BR    
    Brake/cooling ECM     J1-7     892-BR    

    Table 2
    Module     Contact     Wire    
    Transmission ECM     J1-8     893-GN    
    Brake/cooling ECM     J1-8     893-GN    

Expected Result:

The resistance measures less than 5 ohms.

Results:

  • OK - The resistance measures less than 5 ohms. The data link circuit is correct. The ECM may have failed.

    Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this diagnostic code again. Replace the ECM if the cause of the diagnostic code is not found. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    Stop.

  • NOT OK - The resistance that is measured is greater than 5 ohms. The machine harness has failed.

    Repair: The data link circuit is open in the machine harness. Repair the machine harness or replace the machine harness. Verify that the repair eliminates the problem.

    Stop.

Caterpillar Information System:

554 Forwarder and 574 Forwarder Operation
797 and 797B Off-Highway Truck/Tractors Braking System MID 116 - CID 0269 - FMI 04
554 Forwarder and 574 Forwarder Before Operation
Air Conditioning and Heating R-12 All Caterpillar Machines Refrigerant Expansion Valve
14H and 16H Motor Graders Power Train Differential and Bevel Gear - Adjust
554 Forwarder and 574 Forwarder Engine Starting
554 Forwarder and 574 Forwarder Tire Information
Air Conditioning and Heating R-12 All Caterpillar Machines Refrigerant Expansion Valve System
RM-350B Reclaimer/Mixer All Wheel Drive Electronic Control System Connector Contact Description
793C XQ Off-Highway Truck Fan Drive Oil Filter - Replace
554 Forwarder and 574 Forwarder Fire Prevention and Explosion Prevention
797 and 797B Off-Highway Truck/Tractors Braking System MID 116 - CID 0269 - FMI 03
PS-150B and PS-200B Paving Compactors Engine Air Filter Primary Element - Clean/Replace
797 and 797B Off-Highway Truck/Tractors Braking System MID 116 - CID 0296 - FMI 09
Air Conditioning and Heating R-12 All Caterpillar Machines Refrigerant Compressor
Air Conditioning and Heating R-12 All Caterpillar Machines Refrigerant Condenser
554 Forwarder and 574 Forwarder Guards
Air Conditioning and Heating R-12 All Caterpillar Machines Evaporator Coil
797 and 797B Off-Highway Truck/Tractors Braking System MID 116 - CID 0296 - FMI 12
216, 226, 232 and 242 Skid Steer Loaders Machine Systems Tire and Rim
793C XQ Off-Highway Truck Fan Drive Tank Oil - Change
RM-350B Reclaimer/Mixer All Wheel Drive Electronic Control System Switches
IT28G Integrated Toolcarrier and 924G, 924GZ and 928G Wheel Loaders Power Train Transmission Oil Cooler
RM-350B Reclaimer/Mixer All Wheel Drive Electronic Control System Relays
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.