789B Off-Highway Truck Caterpillar


Starting with Jump Start Cables

Usage:

789B 7EK

------ WARNING! ------

Batteries give off flammable fumes that can explode resulting in personal injury.

Prevent sparks near the batteries. They could cause vapors to explode. Do not allow the jump start cable ends to contact each other or the machine.

Do not smoke when checking battery electrolyte levels.

Electrolyte is an acid and can cause personal injury if it contacts skin or eyes.

Always wear eye protection when starting a machine with jump start cables.

Improper jump start procedures can cause an explosion resulting in personal injury.

Always connect the battery positive (+) to battery positive (+) and the battery negative (-) to battery negative (-).

Jump start only with an energy source with the same voltage as the stalled machine.

Turn off all lights and accessories on the stalled machine. Otherwise, they will operate when the energy source is connected.

----------------------


NOTICE

When starting from another machine, make sure that the machines do not touch. This could prevent damage to engine bearings and electrical circuits.

Turn on (close) the battery disconnect switch prior to the boost connection to prevent damage to electrical components on the stalled machine.

Severely discharged maintenance free batteries do not fully recharge from the alternator after jump starting. The batteries must be charged to proper voltage with a battery charger. Many batteries thought to be unusable are still rechargeable.

This machine has a 24 volt starting system. Use only the same voltage for jump starting. Use of a welder or higher voltage damages the electrical system.

Refer to Special Instruction, Battery Test Procedure, SEHS7633, available from your Caterpillar dealer, for complete testing and charging information.


Use of Jump Start Cables

When the auxiliary start receptacles are not available, use the following procedure.

  1. Determine the failure of the engine to start. Refer to Special Instruction, SEHS7768 on the use of 6V-2150 Starting Charging Analyzer Group . Use this procedure if the machine does not have a diagnostic connector.

  1. Move the transmission direction and speed control lever to the NEUTRAL position on the stalled machine. Move all controls to the HOLD position.

  1. On a stalled machine, turn the start switch key to the OFF position. Turn off the accessories.

  1. On a stalled machine, turn the battery disconnect switch to the ON position.

  1. Move the machines together in order for the cables to reach. DO NOT ALLOW THE MACHINES TO CONTACT EACH OTHER.

  1. Stop the engine on the machine that is the electrical source. When you use an auxiliary power source, turn off the charging system.



    Illustration 1g00289965

  1. Check the battery caps for correct placement and for correct tightness. Make these checks on both machines. Make sure that the batteries in the stalled machine are not frozen. Check the batteries for low electrolyte.

  1. Connect the positive jump start cable to the positive cable terminal of the discharged battery.

    Do not allow positive cable clamps to contact any metal except for battery terminals.

  1. Batteries in series may be in separate compartments. Use the terminal that is connected to the starter solenoid. This battery is normally on the same side of the machine as the starter.

  1. Connect the positive jump start cable to the positive terminal of the electrical source. Use the procedure from Step 9 in order to determine the correct terminal.

  1. Connect one end of the negative jump start cable to the negative terminal of the electrical source.

  1. Make the final connection. Connect the negative cable to the frame of the stalled machine. Make this connection away from the battery, the fuel, the hydraulic lines, or moving parts.

  1. Start the engine on the machine that is the electrical source. Also, you can energize the charging system on the auxiliary power source.

  1. Allow the electrical source to charge the batteries for two minutes.

  1. Attempt to start the stalled engine. Refer to Operation and Maintenance Manual, SEBU6518, "Engine Starting". See the beginning of this topic.

  1. Immediately after the stalled engine starts, disconnect the jump start cables in reverse order.

  1. Conclude with a failure analysis on the starting charging system. Check the stalled machine, as required. Check the machine when the engine is running and the charging system is in operation.

Caterpillar Information System:

789B Off-Highway Truck Air System and Brakes Parking Brake System Pressure - Test and Adjust
CP-563C and CS-563C Vibratory Compactors Window Wiper and Washer Control
Schedules For The On-Fuel Injection Test Stand{0782, 1264} Schedules For The On-Fuel Injection Test Stand{0782, 1264}
793B Off-Highway Truck Engine Starting with Jump Start Cables
631E Series II Wheel Tractor-Scrapers Battery or Battery Cable - Inspect/Replace
CP-563C and CS-563C Vibratory Compactors Light Switches
793B Off-Highway Truck Power Train Electronic Control (Transmission Gear Indicator)
793B Off-Highway Truck Power Train Transmission Control
IT14G Integrated Toolcarrier and 914G Wheel Loader Braking System Parking Brake
CP-563C and CS-563C Vibratory Compactors Alert Indicators
784B and 785B Off-Highway Truck/Tractors Air Conditioner Filter - Clean
784B Tractor and 785B Off-Highway Truck Power Train Electronic Programmable Transmission Control (EPTC II)
CP-563C and CS-563C Vibratory Compactors Horn
784B Tractor and 785B Off-Highway Truck Power Train Transmission Neutralizer
CP-563C and CS-563C Vibratory Compactors Backup Alarm
CP-563C and CS-563C Vibratory Compactors Heating Control
793B Off-Highway Truck Power Train Solenoid Valve (Lockup Clutch)
789B Off-Highway Truck Air System and Brakes Towing the Machine - Preparation
539 Knuckleboom Loader General Hazard Information
938G Wheel Loader and IT38G Integrated Toolcarrier Engine Supplement Water Temperature Regulator - Remove and Install
950G Wheel Loader, 962G Wheel Loader and IT62G Integrated Toolcarrier Engine Supplement Water Pump - Remove and Install
539 Knuckleboom Loader Crushing Prevention and Cutting Prevention
784B and 785B Off-Highway Truck/Tractors Model View Illustrations
950G Wheel Loader, 962G Wheel Loader and IT62G Integrated Toolcarrier Engine Supplement Governor and Fuel Transfer Pump - Remove
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.