Magnetic Pick-Up (2301 Control)
Usage:
TYPICAL ILLUSTRATION
(1) Clearance between magnetic pick-up and flywheel ring gear ... .022 to .033 in.(0.56 to 0.84 mm)
NOTE: Turn the pick-up in until it comes in contact with the teeth on the flywheel ring gear. Turn the pick-up out 1/2 turn. This will give .022 to .033 in. (0.56 to 0.84 mm) clearance at (1).
(2) Torque for locknut ... 50 ± 10 lb.ft.(70 ± 14 N·m)
Caterpillar Information System:
D348 INDUSTRIAL & MARINE ENGINES Starting Air Regulating Valve (1L5011)
D348 INDUSTRIAL & MARINE ENGINES Governor (Woodward UG-8)
D348 INDUSTRIAL & MARINE ENGINES Governor Actuator (Woodward EG-3P)
D348 INDUSTRIAL & MARINE ENGINES Primary Fuel Filter
D348 INDUSTRIAL & MARINE ENGINES Shut Off Solenoids
D348 INDUSTRIAL & MARINE ENGINES Oil Pressure Contactor Switches
D348 INDUSTRIAL & MARINE ENGINES Electric Tachometer
D348 INDUSTRIAL & MARINE ENGINES Sending Units For Oil Pressure
D348 INDUSTRIAL & MARINE ENGINES Sending Unit For Water Temperature
D348 INDUSTRIAL & MARINE ENGINES Gauges For Water Temperature
D348 INDUSTRIAL & MARINE ENGINES Gauges For Gear Oil Pressure
D348 INDUSTRIAL & MARINE ENGINES Gauges For Engine Oil Pressure
D348 INDUSTRIAL & MARINE ENGINES Oil Pressure Switch
D348 INDUSTRIAL & MARINE ENGINES Power Take-Off Clutch Groups
D348 INDUSTRIAL & MARINE ENGINES Magnetic Pickup
D348 INDUSTRIAL & MARINE ENGINES Electronic Speed Switch (3N7874 and 3N9595)
D348 INDUSTRIAL & MARINE ENGINES Mechanical Overspeed Shutoff
D348 INDUSTRIAL & MARINE ENGINES Auxiliary Drive
D348 INDUSTRIAL & MARINE ENGINES Governor Air Actuator Linkage
D348 INDUSTRIAL & MARINE ENGINES Air Valves For Air Starting System
D348 INDUSTRIAL & MARINE ENGINES Prelubrication Pump Motor (Electric)
D348 INDUSTRIAL & MARINE ENGINES Governor Air Actuators (2N6006, 1N9318)
D348 INDUSTRIAL & MARINE ENGINES Shut Off Valve (Water Temperature) (4L7108)
D348 INDUSTRIAL & MARINE ENGINES Prelubrication Pump Motor Relay