D348 INDUSTRIAL & MARINE ENGINES Caterpillar


Oil Pressure Contactor Switches

Usage:

9F7837 and 8L4537

Rating when used with alarm or switch:

115 Volt AC ... 15 A

230 Volt AC ... 14 A

115 Volt DC ... 6.5 A

230 Volt DC ... 3.3A

6 to 32 Volt DC ... 14A

9F7837

With an increase of pressure, contacts are activated at ... 12 psi(85 kPa)

With a decrease of pressure, contacts are activated at ... 8 psi(55 kPa)

8L4537

With an increase of pressure, contacts are activated at ... 22 psi(150 kPa)

With a decrease of pressure, contacts are activated at ... 10 psi(70 kPa)

2N6955, 3N531 and 2N7124

Rating when used with alarm or switch:

125, 250 or 480 Volt AC ... 20 A

125 Volt DC ... .5 A

250 Volt DC ... .25 A

2N6955 and 3N531

With an increase of pressure, contacts are activated at ... 12 psi(85 kPa)

With a decrease of pressure, contacts are activated at ... 8 psi(55 kPa)

2N7124

With an increase of pressure, contacts are activated at ... 22 psi(150 kPa)

With a decrease of pressure, contacts are activated at ... 10 psi(70 kPa)

Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.