Usage:
Pressure setting ... 19 300 ± 400 kPa (2800 ± 58 psi)
At a flow of ... 2.0 ± 0.5 liter/min (.50 ± .13 U.S. gpm)
Torque to install valve ... 50 ± 7 N·m (37 ± 5 lb ft)
(1) 2J6089 Spring:
Length under test force ... 36.25 mm (1.427 in)
Test force ... 285.7 to 315.8 N (64.20 to 70.96 lb)
Free length after test ... 44.12 ± 0.51 mm (1.737 ± .020 in)
Outside diameter ... 12.50 mm (.492 in)
9T4752
Pressure setting ... 19 300 ± 400 kPa (2800 ± 58 psi)
At a flow of ... 2.0 ± 0.5 liter/min (.50 ± .13 U.S. gpm)
Torque to install valve ... 50 ± 7 N·m (37 ± 5 lb ft)
(1) 2J6089 Spring:
Length under test force ... 36.25 mm (1.427 in)
Test force ... 285.7 to 315.8 N (64.20 to 70.96 lb)
Free length after test ... 44.12 ± 0.51 mm (1.737 ± .020 in)
Outside diameter ... 12.50 mm (.492 in)
(2) 3J7470 Shim
Thickness of one shim ... 1.22 mm (.048 in)
(3) Torque for locknut ... 35 ± 5 N·m (26 ± 4 lb ft)
9T8482
Pressure setting ... 19 300 ± 400 kPa (2800 ± 58 psi)
At a flow of ... 2.0 ± 0.5 liter/min (.50 ± .13 U.S. gpm)
Torque to install valve ... 50 ± 7 N·m (37 ± 5 lb ft)
(1) Torque for nut ... 18 ± 2 N·m (13 ± 1 lb ft)
(2) 4T5646 Spring:
Length under test force ... 31 mm (1.2 in)
Test force ... 365 ± 29 N (82.0 ± 6.0 lb)
Free length after test ... 36.5 mm ( 1.44 in)
Outside diameter ... 12.45 mm (.490 in)
(3) 4T5645 Spring:
Length under test force ... 31 mm (1.2 in)
Test force ... 92 ± 7.4 N (20.7 ± 1.66 lb)
Free length after test ... 37.2 mm ( 1.46 in)
Outside diameter ... 6.5 mm (.26 in)