1977/10/12 Caterpillar


Use Correct Contact Point With Dial Indicator To Be Sure Of The Accuracy Of The Measurements Of Fuel Setting And Fuel Ratio Control Setting On Sleeve Metering Fuel Systems

Usage:


3208, 3304, 3306 Engines

There are two types of 3P1567 Dial Indicators and a contact point for each type. If the wrong contact point is used with the dial indicator, it is possible that the measurement will not be correct for fuel setting or fuel ratio control setting.

The earlier 3P1567 Dial Indicators did not have a return spring, (but return springs have been added to many of these indicators). The total measurement range for the earlier indicator is approximately .8" (20 mm). The 5P6531 Contact Point is 2.25" (57.2 mm) long and is used with the earlier indicators either with or without return springs.

The later 3P1567 Dial Indicators have a return spring. The total measurement range for the later indicator is approximately 1" (25 mm). The 5P4809 Contact Point is 2.00" (50.8 mm) long and is used with the later indicators.

Since the return spring is not a good identification of earlier or later types, it is necessary to measure the dial indicator with the contact point installed. See dimension A in the illustration. If the correct contact point is used, dimension A will be approximately 3" (76 mm). If dimension A is not approximately 3" (76 mm), the wrong contact point is used.

When the dial indicator and contact are installed in the fuel system and the large hand of the indicator is to be put on zero, be sure the indicator is not moved down more than .08" (2 mm) which is two revolutions of the large hand from the free position (no force on the contact point).


Dial indicator and contact point.

Caterpillar Information System:

1977/09/28 Turbocharger Heat Shields Are Stronger
1977/09/28 Use Viscous (Fluid) Type Crankshaft Vibration Damper In Place Of Rubber Type Damper
1977/09/28 Use Only The Larger Size Inserts To Make A Repair To Cylinder Block Counterbores For Cylinder Liners
1977/09/28 Stronger Piston Is Used; Piston And Connecting Rod Are Tapered In Area Of Piston Pin
1977/09/28 Do Not Use Plastic Tubing With Brass Couplings As A Fuel Supply Line
1977/09/28 Changes To The Injection Pump And The Fuel Setting
1977/09/28 Stronger Fan Drive Pulley Prevents Cracks During Assembly; Torque On Pulley Bolts Changed
1977/09/07 List Of Service Publications
1977/09/07 Check For Extra Holes In Crankshaft Flange If Oil Leaks From Between The Flywheel And Crankshaft Flange
1977/09/07 New Tube Assemblies For Turbocharger Oil Lines; New Base Assemblies For Oil Filters
1977/09/07 Engine Valve Springs Are Now Made Of Stronger Steel
1977/09/07 New Clutch Groups Used In Front Power Take-Offs; Service Kits Available
1977/10/12 If The Fuel Setting Dimension Is More Than 7.00 MM, Remove The End Play Of The Camshaft To Make The Fuel Setting
1977/10/12 New Front Housing Has Stronger Boss For Alternator
1977/10/12 Improved Main, Thrust And Connecting Rod Bearings Have Aluminum Alloy With More Strength
1977/10/12 Improved Oversize And Undersize Connecting Rod And Main Bearings With Higher Strength Aluminum Alloy
1977/10/12 Washer Removed From Variable Timing Unit
1977/10/12 List Of Service Publications
1977/10/12 Fuel Transfer Pump Shaft With Chromium Plate
1977/10/12 Be Sure To Drain Oil From The BrakeSaver At Every Lubricating Oil Change Period
1977/10/26 Fabricated Extension Prevents Fuel "Splash" During Injection Valve Testing
1977/10/26 Preparation Of Truck Engines For Cold Weather Operation
1977/10/26 Replacement Bearings Have Aluminum Alloy With More Strength
1977/10/26 Troubleshooting The Tachometer System Of The 4S6553 Engine Instrument Group
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.