Selective Catalytic Reduction Retrofit Aftertreatment - Airless Dosing Caterpillar


DEF Control Module Temperature Is High

Usage:

SCR PF3

Table 1
J1939 Code and Description  CDL Code and Description  Comments 
5480-16
Aftertreatment #1 DEF Controller Temperature : High - moderate severity (2) 
E14130(2)
High Aftertreatment #1 DEF Controller #1 Temperature 
The temperature of the Dosing Control Unit (DCU) has exceeded the trip point of 116° C (240° F). 


Illustration 1g06194551
DCU

Complete the procedure in the order in which the steps are listed.

Table 2
Troubleshooting Test Steps  Values  Results 

1. Determine the Source of the High Temperature

A. Evaluate the installation location of the DCU.

B. Check for heat sources close to the DCU.
 

Heat Source 

Result: The DCU is located close to a heat source.

Repair: Eliminate the heat source by installing a heat shield or moving the component creating the heat.

Proceed to Test Step 2.
 

2. Replace the DCU

A. Replace the DCU.
 

DCU 

Result: The DCU was replaced.

Verify that the problem is resolved.
 

If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).

Caterpillar Information System:

Selective Catalytic Reduction Retrofit Aftertreatment - Airless Dosing Diagnostic Trouble Codes
Selective Catalytic Reduction Retrofit Aftertreatment - Airless Dosing Configuration Parameters
Selective Catalytic Reduction Retrofit Aftertreatment - Airless Dosing Electrical Connectors
Selective Catalytic Reduction Retrofit Aftertreatment - Airless Dosing Diagnostic Capabilities
Marine Selective Catalytic Reduction (SCR) Retrofit Aftertreatment Warranty Information
Selective Catalytic Reduction Retrofit Aftertreatment - Airless Dosing Component Location
C175 Tier 4 Final Engines for Caterpillar Built Machines Engine Oil Pump - Remove
Selective Catalytic Reduction Retrofit Aftertreatment - Airless Dosing Electronic Service Tools
Selective Catalytic Reduction Retrofit Aftertreatment - Airless Dosing Welding Precaution
3516B Generator Set Engines with Dynamic Gas Blending Centrifugal Oil Filters
Selective Catalytic Reduction Retrofit Aftertreatment - Airless Dosing General Information
Marine Selective Catalytic Reduction (SCR) Retrofit Aftertreatment Catalyst (SCR) - Replace
Selective Catalytic Reduction Retrofit Aftertreatment - Airless Dosing DEF Module Does Not Respond
Selective Catalytic Reduction Retrofit Aftertreatment - Airless Dosing DEF Tank Level Is Low
Selective Catalytic Reduction Retrofit Aftertreatment - Airless Dosing Data Link - Test
C8.7 and C12.9 Marine Engines Sensor Supply - Test
323F SA and 323F LN Excavator Declaration of Conformity
C280 Marine Engines Valve Mechanism
C280 Marine Engines Fuel Injector Mechanism
Valve Mechanism Cover Seal on Certain C7.1 Engines {1107} Valve Mechanism Cover Seal on Certain C7.1 Engines {1107}
Valve Mechanism Cover Seal on Certain C7.1 Machine Engines {1107} Valve Mechanism Cover Seal on Certain C7.1 Machine Engines {1107}
C280 Marine Engines Cylinder Block
3516B Generator Set Engines with Dynamic Gas Blending Testing the Cooling System
Marine Selective Catalytic Reduction (SCR) Retrofit Aftertreatment Maintenance Interval Schedule
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.