C7.1 Engines and Generator Sets Caterpillar


Indicator Lamp Problem

Usage:

C7.1 770
Note: This procedure is only applicable to applications that have individual indicator lamps.

Use this procedure under the following circumstances:

  • The lamps are not receiving battery voltage.

  • The lamps are not operating correctly.

The following diagnostic lamps are available:

  • Wait to start lamp

  • DPF regen disabled lamp

  • Low oil pressure lamp

  • Regeneration active lamp

  • Wait to disconnect lamp

  • DPF lamp

  • Shutdown lamp

  • Warning lamp

The electronic service tool can be used as a diagnostic aid to switch the individual lamps ON and OFF.

Note: The diagnostic aid that switches the lamps is contained in the "Override" section in the "Diagnostics" menu of the electronic service tool.

During the following procedure, refer to the electrical schematic for the application.

Complete the procedure in the order in which the steps are listed.

Table 1
Troubleshooting Test Steps  Values  Results 

1. Inspect Electrical Connectors and Wiring

A. Turn the keyswitch to the OFF position.

B. Check that the fuses are not blown.

C. Thoroughly inspect the P1 connector and the lamp connections. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.

D. Perform a 45 N (10 lb) pull test on each of the wires in the P1 connector that are associated with the indicator lamps.

E. Check the screw for the ECM connector for the correct torque of 6 N·m (53 lb in).

F. Check the harness for abrasions and for pinch points from the battery to the ECM.
 

Loose connection or damaged wire
 

Result: There is a fault in a connector or the wiring.

Repair: Repair any faulty connectors or replace the wiring harness. Ensure that all the seals are properly in place and ensure that the connectors are correctly coupled.

Replace any blown fuses.

Use the electronic service tool to verify that the repair eliminates the fault.

Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points. The fuses are not blown.

Proceed to Test Step 2.
 

2. Inspect the Lamp

A. Disconnect the lamp from the harness. Inspect the lamp to determine if the lamp has failed.

B. Measure the resistance across the two terminals of the lamp.
 

Less than 2000 Ohms
 

Result: The lamp has greater than 2000 Ohms resistance.

Repair: Replace the suspect lamp.

Use the electronic service tool to verify that the repair eliminates the fault.

Result: The lamp has less than 2000 Ohms resistance.

Proceed to Test Step 3.
 

3. Measure the Input Voltage to the Lamp at the Lamp Socket

A. Turn the keyswitch to the ON position.

B. Use the electronic service tool to select the "override" function to switch individual lamps ON and OFF.

Note: The "Override" function is contained in the "Diagnostics" menu of the electronic service tool.

C. Measure the voltage at the lamp socket.
 

At least 10 VDC for a 12 V system.
At least 22 VDC for a 24 V system.
 

Result: The voltage is not within the expected range. The fault is in the battery supply wiring to the lamp.

Repair: Repair the faulty wiring or replace the faulty wiring.

Use the electronic service tool to verify that the repair eliminates the fault.

Result: The voltage is within the expected range.

Proceed to Test Step 4.
 

4. Check the Wiring for an Open Circuit

A. Turn the keyswitch to the OFF position.

B. Disconnect the P1 connector.

C. Remove the bulb from the suspect lamp.

D. Measure the resistance between the ground connection on the lamp holder and the applicable terminal on the P1 connector.
 

Less than 2.0 Ohms
 

Result: The measured resistance is greater than 2.0 Ohms - the fault is in the wiring between the lamp holder and the ECM.

Repair: Repair the faulty wiring or replace the faulty wiring.

Use the electronic service tool to verify that the repair eliminates the fault.

Result: The measured resistance is less than 2.0 Ohms.

Proceed to Test Step 5.
 

5. Check the Wiring for a Short Circuit

A. Disconnect the P1 connector.

B. Check the resistance between the terminal for the suspect lamp and all the other terminals on the P1 connector.
 

Greater than 100 Ohms
 

Result: One or more of the measured resistances is less than 100 Ohms. There is a short in the wiring between the lamp holder and the ECM.

Repair: Repair the faulty wiring or replace the faulty wiring.

Use the electronic service tool to verify that the repair eliminates the fault.

Result: All resistance measurements are greater than 100 Ohms.

Contact the Dealer Solutions Network (DSN).
 

Caterpillar Information System:

C7.1 Engines and Generator Sets Idle Validation - Test
A New Lower Radiator Hose Is Used on Certain 980K Wheel Loaders {1380} A New Lower Radiator Hose Is Used on Certain 980K Wheel Loaders {1380}
994K Wheel Loader Machine Systems Oil Filter (Implement Pump Case Drain) - Remove and Install
Diesel Exhaust Fluid (DEF) Pump Troubleshooting on Certain C4.4 Machine Engines {108J, 108K, 108T, 1901, 1920} Diesel Exhaust Fluid (DEF) Pump Troubleshooting on Certain C4.4 Machine Engines {108J, 108K, 108T, 1901, 1920}
994K Wheel Loader Machine Systems Oil Filter (Implement Pilot) (Front Pump Drive) - Remove and Install
994K Wheel Loader Machine Systems High Pressure Screen (Implement) - Remove and Install
994K Wheel Loader Machine Systems Gear Pump (Steering Oil Cooler) - Remove and Install
D9R Track-Type Tractor Systems Track Roller (Single Flange)
D8T TRACK-TYPE TRACTORS Machine Systems Bottom Guard
New Injector Sleeve on Certain C4.4 and C7.1 Machine Engines {1254, 1290, 1713} New Injector Sleeve on Certain C4.4 and C7.1 Machine Engines {1254, 1290, 1713}
D8R and D8T TRACK-TYPE TRACTORS Machine Systems Muffler
New Injector Sleeve on Certain C4.4 and C7.1 Engines {1254, 1290, 1713} New Injector Sleeve on Certain C4.4 and C7.1 Engines {1254, 1290, 1713}
950GC Wheel Loader Engine Supplement Clean Emissions Module - Remove and Install
C7.1 Engines and Generator Sets Injector Data Incorrect - Test
C7.1 Engines and Generator Sets Injector Solenoid - Test
C7.1 Engines and Generator Sets Mode Selection - Test
C7.1 Engines and Generator Sets Motorized Valve - Test
Improved Grill Mounting Hardware Is Now Available on Certain Large Wheel Loaders and Wheel Dozers {7170, 7263, 7273} Improved Grill Mounting Hardware Is Now Available on Certain Large Wheel Loaders and Wheel Dozers {7170, 7263, 7273}
994K Wheel Loader Machine Systems Expansion Tank - Remove and Install
992K Wheel Loader Calibrations (Operator Monitor)
994K Wheel Loader Machine Systems Relief Valve (Pilot) - Remove and Install
New Extension Pipe for Precleaner Is Now Available on Certain 992K Large Wheel Loaders {1055} New Extension Pipe for Precleaner Is Now Available on Certain 992K Large Wheel Loaders {1055}
950 GC Wheel Loader Power Train Differential (Standard)
PL61 Pipelayer Machine Systems Boom Winch, Hook Winch and Winch Frame - Remove and Install
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.