Illustration 1 | g02682357 |
Outputs of the Advisor |
The Advisor sends electrical signals through the outputs. The outputs can create an action or provide information to other ECMs on the data link. The ECM can generate output signals to the system components by using: ON/OFF driver outputs, sinking driver outputs, sensor power supply outputs and data link output.
Illustration 2 | g00583116 |
(1) Schematic of Action Alarm
(2) Action Alarm |
The Action Alarm is activated by the Indication Display. Activation of the Action Alarm occurs when there is a parameter that is out of the proper range. Also, the Action Alarm is activated whenever there is an active diagnostic fault.
Illustration 3 | g01476955 |
The action lamp is a red LED indicator that is controlled by the Indication Display. Illumination of the LED occurs when a condition needs immediate attention. The LED lamp is connected to the following pin on the Indication Display: J2-1 411-PK(Pink).