D6N Track-Type Tractor Caterpillar


MID 039 - CID 2212 - FMI 04

Usage:

D6N LGP PBA
Conditions Which Generate This Code:


Illustration 1g02641417

Connections of the ripper raise solenoid

This diagnostic code is associated with solenoid "A" on valve 1. The FMI 04 means that the ECM has determined that either an open in the circuit or a short to ground exists.

The possible causes are listed:

  • The return circuit of the solenoid is shorted to ground.

  • The energize circuit of the solenoid is open.

  • The return circuit of the solenoid is open.

  • The solenoid has failed.

  • The ECM has failed. ECM failure is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 2212 FMI 04 is active before performing this procedure.

Note: Use a digital multimeter for the measurements in this procedure.

Note: Check the configuration of your machine for the number of implement electronic control modules. The following table lists some of the configurations that are available:

Table 1
Machines with one Electronic Implement Control    
Electronic Implement Control     Fourth Valve, Ripper, or Winch    

Test Step 1. CHECK THE RETURN CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.

  1. Turn the disconnect switch and the key start switch to the OFF position.

  1. Disconnect the solenoid from the machine harness.

  1. Disconnect the machine harness at the valve ECM.

  1. At the harness connector for the ECM, measure the resistance from the supply wire to all contacts that are used in the machine harness connector.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • YES - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.

  • NO - Each resistance measurement is NOT greater than 5000 ohms. There is a short in the machine harness between the supply wire and the circuit with the low resistance measurement.

    Repair: Repair the machine harness or replace the machine harness.

    STOP

Test Step 2. CHECK THE HARNESS FOR AN OPEN.

  1. The key start switch and the disconnect switch remain in the OFF position.

  1. The machine harness remains disconnected from the valve ECM.

  1. The solenoid remains disconnected from the machine harness.

  1. At the machine harness connector for the solenoid, place a jumper wire from contact 1 to contact 2.

  1. At the machine harness connector for the valve ECM, measure the resistance from the supply wire to the return wire.

Expected Result:

The resistance should be less than 5.0 ohms.

Results:

  • OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.

    Repair: The open is in the supply wire or the return wire of the machine harness. Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK THE SOLENOID.

  1. Remove the jumper wire from the previous Test Step.

  1. Reconnect the machine harness to the valve ECM.

  1. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.

  1. The solenoid remains disconnected from the machine harness.

  1. At the machine harness connector for the solenoid, place a jumper wire from contact 1 to contact 2.

  1. Observe the status of the diagnostic code.

Expected Result:

The diagnostic code is active. The diagnostic code changes from "FMI 04" to "FMI 06" after the jumper wire is installed.

Results:

  • YES - The diagnostic code changes from "FMI 04" to "FMI 06" after the jumper wire is installed.

    Repair: Repeat this test in order to verify that the solenoid has failed. Replace the solenoid. See the Testing and Adjusting, KENR5705, "Calibration" procedure in the service manual for your machine.

    STOP

  • NO - The "FMI 04" diagnostic code remains active. Proceed to test step 4.

Test Step 4. CHECK IF THE DIAGNOSTIC CODE REMAINS.

  1. Inspect the harness connectors. Clean the contacts of the harness connectors. Check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.

  1. Reconnect all harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each connector are fastened.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Check the status of the diagnostic code.

Expected Result:

The diagnostic code is active.

Results:

  • YES - The diagnostic code is active. The diagnostic code has not been corrected.

    Repair: Check the circuit again. ECM failure is unlikely. Exit this procedure and perform this procedure again. Prior to replacing an ECM, always contact your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM requires replacement, refer to Troubleshooting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The diagnostic code is not active. The initial diagnostic code may have been caused by a poor electrical connection that was corrected when a harness connector was disconnected and reconnected. Resume normal machine operation.STOP

Caterpillar Information System:

D6N Track-Type Tractor MID 039 - CID 0590 - FMI 14
D6N Track-Type Tractor MID 039 - CID 0672 - FMI 02
D6N Track-Type Tractor MID 039 - CID 1198 - FMI 13
992K Wheel Loader Cooling System Coolant Extender (ELC) - Add
D6N Track-Type Tractor MID 039 - CID 1197 - FMI 13
D6N Track-Type Tractor MID 039 - CID 1251 - FMI 04
D6N Track-Type Tractor MID 039 - CID 1326 - FMI 02
D6N Track-Type Tractor MID 039 - CID 0041 - FMI 03
D6N Track-Type Tractor MID 039 - CID 1198 - FMI 03
D6N Track-Type Tractor MID 039 - CID 1198 - FMI 05
D6N Track-Type Tractor MID 039 - CID 1198 - FMI 06
D6N Track-Type Tractor MID 039 - CID 2596 - FMI 03
D3K2, D4K2 and D5K2 Track-Type Tractors Power Train Track Carrier Roller
992K Wheel Loader Cooling System Coolant Level - Check
621H, 623H and 627H Wheel Tractor-Scrapers Implement Electronic Control System General Information
621H, 623H and 627H Wheel Tractor-Scrapers Implement Electronic Control System Automatic Return Function for the Ejector Does Not Operate
2011/08/25 New Seat Now Used on AD30 Underground Articulated Truck {7312, 7324}
374F Excavator Machine System Hydraulic Pedal Control (Auxiliary)
3500 Engines Turbocharger
C3.4B Industrial Engine Fuel System Secondary Filter - Replace
2011/06/10 Procedure for Releasing Stuck Buttons Due to Rapid Altitude Changes for Certain Advisor Displays {7490}
621H, 623H and 627H Wheel Tractor-Scrapers Implement Electronic Control System Float Function for the Apron Does Not Operate
621H, 623H and 627H Wheel Tractor-Scrapers Implement Electronic Control System Quick Drop Function for the Bowl Does Not Operate
621H, 623H and 627H Wheel Tractor-Scrapers Implement Electronic Control System Solenoid Calibration Is Not Successful
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.