816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer Caterpillar


MID 081 - CID 1693 - FMI 03

Usage:

814F II BXG
Conditions Which Generate This Code:


Illustration 1g01341036

Schematic for the Position Sensor (Decelerator Pedal)

This diagnostic code is associated with the Position Sensor (Decelerator Pedal). The FMI 03 means that the ECM has determined that the voltage of the circuit for the sensor is above normal.

The possible causes of this diagnostic code are listed below:

  • The signal circuit for the sensor is open.

  • The signal circuit for the sensor is shorted to the +battery circuit.

  • The sensor has failed.

  • The power circuit or the ground circuit has failed.

  • Machine Response: The DECEL pedal will stop working.

  • The ECM has failed. This is unlikely.

Note: This is a PWM sensor with an operating frequency of 5000Hz and a normal duty cycle operating range of 3.5% to 96.5%.

Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.

  • The ECM has failed. This is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1693 FMI 03 is active before performing this procedure.

Test Step 1. CHECK FOR POWER AT THE SENSOR.

  1. Do not disconnect the harness connector from the sensor.

  1. Turn the key start switch and the disconnect switch to the ON position.

  1. At the back of the harness connector for the sensor, insert a 7X-1710 Multimeter Probe along the voltage supply wire (contact A).

  1. Measure the voltage from contact A to frame ground.

Expected Result:

The voltage is 24 DCV.

Results:

  • OK - The voltage is 24 DCV. Proceed to Test Step 2.

  • NOT OK - The voltage is not 24 DCV. The + battery circuit in the machine harness has failed.

    Repair: Replace the machine harness or repair the machine harness.

    STOP

Test Step 2. CHECK FOR PROPER GROUND AT THE SENSOR.

  1. The machine harness remains connected to the sensor.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  1. Remove the 7X-1710 Multimeter Probe from the voltage supply wire (contact A).

  1. At the back of the harness connector for the sensor, insert a 7X-1710 Multimeter Probe along the ground wire (contact B).

  1. Measure the resistance from contact B to frame ground.

Expected Result:

The resistance is less than 5 ohms.

Results:

  • OK - The resistance is less than 5 ohms. The ground circuit is correct. Proceed to Test Step 3.

  • NOT OK - The resistance is greater than 5 ohms. The ground circuit in the machine harness has failed.

    Repair: Replace the machine harness or repair the machine harness.

    STOP

Test Step 3. CHECK THE WIRING HARNESS OF THE SENSOR FOR AN OPEN CIRCUIT.

  1. The key start switch and the disconnect switch remain in the OFF position.

  1. Disconnect the machine harness from the sensor.

  1. At the harness connector for the sensor, connect a jumper wire between contact B and contact C.

  1. Disconnect the machine harness connector(s) from the ECM.

  1. At the harness connector for the ECM, measure the resistance between contact J2-4 (wire H722-GN) and contact J1-16 (wire 202-BK).

Expected Result:

The resistance measurement is less than 5 ohms.

Results:

  • OK - The resistance measurement is less than 5 ohms. The circuit is correct. Proceed to Test Step 4.

  • NOT OK - The resistance is greater than 5 ohms. The circuit is not correct. There is an open circuit in the wiring harness.

    Repair: There is an open circuit in the wiring harness. Repair the wiring harness or replace the wiring harness.

    STOP

Test Step 4. CHECK THE WIRING HARNESS OF THE SENSOR FOR A SHORT TO THE +BATTERY CIRCUIT.

  1. The key start switch and the disconnect switch remain in the OFF position.

  1. The machine harness remains disconnected from the sensor. Remove the jumper wire that was installed in the previous step.

  1. The machine harness connector(s) remains disconnected from the ECM.

  1. At the machine harness connector for the ECM, measure the resistance from the signal contact J2-4 (wire H722-GN) of the machine harness to all contacts that are used in the machine harness connectors for the ECM.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 5.

  • NOT OK - One or more resistance measurements is not correct. There is a short in the machine harness.

    Repair: The short is between signal contact J2-4 (wire H722-GN) and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.

    STOP

Test Step 5. CHECK THE OUTPUT OF THE SENSOR.

  1. Reconnect the machine harness connectors to the ECM. Reconnect the machine harness connector to the sensor.

  1. At the back of the harness connector for the sensor, insert a 7X-1710 Multimeter Probe along the signal wire (contact C).

  1. At the back of the harness connector for the sensor, insert a 7X-1710 Multimeter Probe along the ground wire (contact B).

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Measure the signal of the sensor.

Expected Result:

The signal from the sensor is valid.

Results:

  • OK - The signal from the sensor is valid. Proceed to Test Step 6.

  • NOT OK - The signal from the sensor is not valid.

    Repair: The sensor has failed. Replace the sensor.

    STOP

Test Step 6. CHECK IF THE DIAGNOSTIC CODE REMAINS.

  1. Inspect the contacts of the harness connectors and clean the connectors.

  1. Reconnect all harness connectors.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Check the status of the CID 0670 FMI 03.

Expected Result:

The CID 0670 FMI 03 is active.

Results:

  • YES - The CID 0670 FMI 03 is active. The diagnostic code has not been corrected. The ECM may have failed.

    Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 0670 FMI 03 is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

Replacement of the 124-4672 Pressure Sensor for the Payload Control System {1439, 7494} Replacement of the 124-4672 Pressure Sensor for the Payload Control System {1439, 7494}
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1693 - FMI 01
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1693 - FMI 00
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 0562 - FMI 09
D6T Track-Type Tractor Hydraulic System Control Valve (Bulldozer Tilt) - Standard
953D Track-Type Loader Hydraulic System Lift Circuit
2007/01/01 Improved End Bits and the Rework Procedure are Available for the Bulldozer Blade {6804}
IT38H Integrated Toolcarrier and 938H Wheel Loader Engine Supplement Engine Compartment Shield - Remove and Install
AD55B Underground Articulated Truck Power Train Electronic Control System Backup Alarm Always On
AD55B Underground Articulated Truck Power Train Electronic Control System System Schematic
AD55B Underground Articulated Truck Power Train Electronic Control System Electronic Control Module (ECM) - Replace
AD55B Underground Articulated Truck Power Train Electronic Control System Hoist System Enable - Check
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1693 - FMI 04
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1693 - FMI 13
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1711 - FMI 03
IT38H Integrated Toolcarrier and 938H Wheel Loader Engine Supplement Fan and Gear Motor (Hydraulic Fan) - Remove
IT62H Integrated Toolcarrier and 950H and 962H Wheel Loaders Sound Information and Vibration Information
2007/01/15 Special Tall Flange Rollers Are Now Available {4180}
AD55B Underground Articulated Truck Power Train Electronic Control System Backup Alarm Always Off
3306C Engines for Caterpillar Built Machines Fan Drive
C4.4 and C6.6 Engines for Caterpillar Built Machines System Configuration Parameters
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1711 - FMI 04
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1757 - FMI 03
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1757 - FMI 04
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.