- Wheel Loader:
- 988F Series II (S/N: 2ZR1-UP)
- 988F (S/N: 8YG1-UP)
- 990 Series II (S/N: 4FR1-UP)
- 990 (S/N: 7HK1-UP)
- 988F (S/N: 8YG1-UP)
Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.
Problem
There have been reports of problems with compatibility between Caterpillar Electronic Technician and some change levels of 158-5003 Monitor Electronic Control Module or 0R-7064 Electronic Control Gp . These issues may occur when the 171-4401 Communication Adapter As is used. The Cat Data Link communication link is lost. Refer to Table 1 for a list of fault codes that are logged.
Model     | Fault Codes     |
988F 988F Series II     |
26-248-F02 81-248-F12 81-590-F09 36-296-F09     |
990 990 Series II     |
0296-09 0599-09     |
Solution
This problem was not encountered when the older 7X-1701 Communication Adapter As was used. If this problem is encountered, Cat ET can be used with the 7X-1701 Communication Adapter As . Alternately, the panel for the Computerized Monitoring System can be unplugged while ET is being used.