C-10, C-12 and C-15 On-highway Engines Caterpillar


Output Selections

Usage:

C-10 MBJ

"Engine Running Output"

Output 2, output 3, or output 4 is available for the connection of an engine running output relay that is used to prevent engagement of the starter while the engine is running. The "Engine Running Output" can be programmed to J1/P1:10, to J1/P1:12 or to J1/P1:13. The "Engine Running Output" comes on when the engine is running. The "Engine Running Output" turns off when the engine rpm is 0. The relay is normally closed so cranking can be achieved immediately at powerup. During cranking, the ECM energizes the "Engine Running Output" once engine low idle rpm has been achieved. The relay is de-energized when the engine speed falls by 100 rpm below the programmed low idle. The programmed low idle range is 600 rpm to 750 rpm.

Table 1
Alternative     Default    
"J1/P1:10"
"J1/P1:12"
"J1/P1:13"    
"None"    

"Engine Shutdown Output"

Output 2, output 3 or output 4 is available for the connection of an engine shutdown output relay that is used to shut down the vehicle electrical system after the idle timer has expired. The "Engine Shutdown Output" can be programmed to J1/P1:10, to J1/P1:12 or to J1/P1:13. The "Engine Shutdown Output" comes on after the engine runs for more than three seconds. The "Engine Shutdown Output" turns off when the engine rpm is at least 100 rpm below the low idle rpm for more than three seconds.

Table 2
Alternative     Default    
"J1/P1:10"
"J1/P1:12"
"J1/P1:13"    
"None"    

"Auxiliary Brake"

The auxiliary brake output is for use with a BrakeSaver or other aftermarket braking devices. Output 3 is available for the connection of an auxiliary brake relay. This parameter ("Auxiliary Brake") must be programmed to J1/P1:12. Operation of the auxiliary brake and the relay is inhibited during undesirable engine operating conditions. The time period of fueling the engine is an undesirable engine operating condition.

Table 3
Alternative     Default    
"J1/P1:12"     "None"    

"Starting Aid Output"

Output 2, output 3 or output 4 is available for the connection of the starting aid relay or the starting aid solenoid. If a starting aid switch is not used, the starting aid output will turn on automatically when operating conditions require the use of a starting aid. If the "Starting Aid On/Off Switch" parameter is programmed and a switch connected to the corresponding switch input, the starting aid output will not function when the switch is in the OFF position.

Table 4
Alternatives     Default    
"J1/P1:10"
"J1/P1:12"
"J1/P1:13"    
"None"    

"Air Inlet Shutoff Relay Control"

The air inlet shutoff is available for certain engine ratings that operate in areas with large amounts of combustible gases. The air inlet shutoff will protect the engine from an engine overspeed when these gases are present. If this option is installed, the "Air Inlet Shutoff Relay Control" cannot be turned off. J1/P1:62 must be connected to the +Battery in order for the air inlet shutoff to operate. If a neutral switch is installed in the vehicle, the neutral switch must be connected to J1/P1:62. The air inlet shutoff will only operate when the transmission is in neutral.

Table 5
Alternatives     Default    
"J2/P2:13"     "None"    

"Fan Control Type"

If the ECM is used to operate the cooling fan, this parameter must be programmed to "On/Off", to "Three-Speed Fan", or to "Variable Speed Fan Option S". This parameter must be programmed to "None" if the ECM is not operating the cooling fan relay or the cooling fan solenoid.

Table 6
Alternative     Default    
"On/Off"
"Three-Speed Fan"
"Variable Speed Fan Option S"    
"None"    

"PTO Active Output"

The "PTO Active Output" parameter allows the use of an output when the engine is in PTO mode. The PTO switch must be on in order for the "PTO Active Output" to function. The "PTO Active Output" will stay active until there is a kickout of PTO mode or the PTO switch is turned to the OFF position.

Table 7
Alternative     Default    
"J1/P1:19"     "None"    

Caterpillar Information System:

C-10, C-12 and C-15 On-highway Engines Input Selections
C-10, C-12 and C-15 On-highway Engines Trip Parameters
C-10, C-12 and C-15 On-highway Engines Maintenance Parameters
C-10, C-12 and C-15 On-highway Engines Engine Monitoring Parameters
C11, C13 and C15 On-highway Engines Smart Idle Parameters
C11, C13 and C15 On-highway Engines Timer Parameters
C-10, C-12 and C-15 On-highway Engines Engine/Gear Parameters
C-10, C-12 and C-15 On-highway Engines Dedicated PTO Parameters
Alternator - Delco 27SI Capacitor - Test
G3520B Engines E860 Cyl #20 Exhaust Port Temp Deviating Low
G3520B Engines E859 Cyl #19 Exhaust Port Temp Deviating Low
G3520B Engines E858 Cyl #18 Exhaust Port Temp Deviating Low
C-10, C-12 and C-15 On-highway Engines Data Link Parameters
C11, C13 and C15 On-highway Engines Driver Reward
C11, C13 and C15 On-highway Engines Vehicle Activity Report Parameters
3512 and 3516 EUI Engines and 784B, 785B, 789B and 793B Off-Highway Truck/Tractors Aftercooler
3054E Industrial Engine Engine Design
G3520B Engines Analog Sensor Signal
C-10, C-12 and C-15 On-highway Engines Diagnostic Codes
G3520B Engines Desired Speed Input (4 - 20 mA)
3500 and 3500B High Displacement Engines for Caterpillar Built Machines Air Starting Motor - Assemble
3500 and 3500B High Displacement Engines for Caterpillar Built Machines Air Starting Motor - Disassemble
3500 and 3500B High Displacement Engines for Caterpillar Built Machines Air Starting Motor - Install
3500 and 3500B High Displacement Engines for Caterpillar Built Machines Air Starting Motor - Remove
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.