Electronic Modular Control Panel II (EMCP II) Caterpillar


GSC CID 0590 - FMI 09

Usage:

3406B 4JK
Conditions Which Generate This Code:

This diagnostic code is associated with" EUI" applications. The CID 0590 failure means that the engine electronic control module has stopped responding to the periodic requests for information from the GSC.

Note: This diagnostic code may occur on an "MUI "application. The diagnostic code is caused by an incorrectly programmed P23 setpoint. For" MUI "applications, the setpoint P23of GSC must be set to 0. Reprogram the setpoint and other GSC setpoints. See Systems Operation, "Engine/Generator Programming OP5".

Test Step 1. CHECK THE CAT DATA LINK

  1. Turn the ECS to OFF/RESET position.

  1. Disconnect the contacts 19 and 20 of the CAT data link from the GSC.

  1. Disconnect the contacts 6 and 7 of the CAT data link from the ECM.

  1. Measure the resistance between contact 19 of the GSC and contact 7 of the ECM.

  1. Measure the resistance between contact 20 of the GSC and contact 6 of the ECM.

Expected Result:

The resistance for both measurements is less than 5 ohms.

Results:

  • OK - The resistance for both measurements is less than 5 ohms. The circuit is correct. The ECM has failed.

    Repair: It is unlikely that the ECM has failed. See Troubleshooting, RENR2227, "3406E and 3456 EPG Engines" prior to replacing the ECM. Clear the diagnostic code from the fault log after troubleshooting is complete. The GSC is usually programmed to treat a CID 590 diagnostic code as an "alarm fault". Setpoint P04 is 0. If the GSC is programmed to treat this code as a shutdown fault, setpoint P04 is 1. Then, it is not necessary to press the "alarm codes" key in order to see the diagnostic code. The diagnostic code is automatically shown on the upper display.

    Stop.

  • NOT OK - The resistance for both measurements is greater than 5 ohms. The circuit is not correct.

    Repair: Repair the wiring of the CAT data link or replace the wiring of the CAT data link.Clear the diagnostic code from the fault log after troubleshooting is complete. The GSC is usually programmed to treat a CID 590 diagnostic code as an "alarm fault". Setpoint P04 is 0. If the GSC is programmed to treat this code as a shutdown fault, setpoint P04 is 1. Then, it is not necessary to press the "alarm codes" key in order to see the diagnostic code. The diagnostic code is automatically shown on the upper display.

    Stop.

Caterpillar Information System:

Electronic Modular Control Panel II (EMCP II) GSC CID 0560 - FMI 11
3054 and 3056 Industrial and Generator Set Engines Fuel System - Prime
3054 and 3056 Engines 550 Generator Set Control Panel Control Module - Configure
385B Excavator Machine System Specifications Stick Lines
Electronic Modular Control Panel II (EMCP II) GSC CID 0444 - FMI 12
385B Excavator Machine System Specifications Stick Lines
2002/04/01 Improved Spark Plug Adapters Help Prevent Seizures of the Spark Plugs {1555}
3054 and 3056 Engines 550 Generator Set Control Panel Control Module
3500 Engines for Caterpillar Built Generator Sets Governor Drive
Electronic Modular Control Panel II (EMCP II) GSC CID 0334 - FMI 04 (for MUI Engines)
Electronic Modular Control Panel II (EMCP II) GSC CID 0334 - FMI 03 (for MUI Engines)
3054E Industrial Engine Engine Oil Pan
C0.5, C0.7, C1.1/3011C, C1.5/3013C, C1.6 and C2.2/3024C/3024CT Industrial Engines and Engines for Caterpillar Built Machines General Information
3126B and 3126E On-highway Engines Fuel Level Sensor Circuit - Test
CIPI UNDERCARRIAGE Arrangements: 9Q-5262, 191-4041, and 204-9207 Travel Brake Valve - Disassemble
UPS 250, UPS 300, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supply Operating Parameters
3126 HEUI Industrial Engine Flywheel - Remove
3126 HEUI Industrial Engine Flywheel - Install
Electronic Modular Control Panel II (EMCP II) GSC CID 0248 - FMI 09
Electronic Modular Control Panel II (EMCP II) GSC CID 0330 - FMI 07
Electronic Modular Control Panel II (EMCP II) GSC CID 0331 - FMI 02
CIPI UNDERCARRIAGE Arrangements: 9Q-5262, 191-4041, and 204-9207 Travel Brake Valve - Assemble
CIPI UNDERCARRIAGE Arrangements: 9Q-5262, 191-4041, and 204-9207 Travel Motor - Remove
CIPI UNDERCARRIAGE Arrangements: 9Q-5262, 191-4041, and 204-9207 Travel Motor - Disassemble
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.