Operator Configuration Mode
The configuration mode allows the operator limited customizing of the way the module operates.
Illustration 1 | g00844791 |
In order to enter the OPERATOR CONFIGURATION MODE, press the UP key and the DOWN key at the same time.
Illustration 2 | g00844409 |
Mode Select Key |
The module will enter OPERATION CONFIGURATION MODE. The OPERATOR CONFIGURATION MODE INDICATOR will illuminate above the MODE SELECT KEY.
Operation     | Detail     |
---|---|
The display will then show the following message:     | CONFIGURATION     |
Illustration 3 | g00844409 |
Mode Select Key |
In order to view the different configuration functions, press the MODE SELECT KEY.
Operation     | Detail     |
---|---|
The display will then show the following message:     | LANGUAGE ENGLISH     |
Illustration 4 | g00844793 |
Press the Up key or press the DOWN key in order to change the language that is selected.
Operation     | Detail     |
---|---|
The display will then show the new language:     | LANGUAGE French     |
Repeat until the required language is displayed:     | LANGUAGE GERMAN     |
Illustration 5 | g00844409 |
Mode Select Key |
Press the MODE SELECT KEY in order to view the next function.
The display will show the following message:
Illustration 6 | g00845090 |
Illustration 7 | g00844793 |
Press the UP key or the DOWN key in order to move the sliding bar UP (Darker) or DOWN (Lighter). Set the bar to the desired position.
Illustration 8 | g00844409 |
Mode Select Key |
When the position is correct, press the MODE SELECT KEY in order to view the next function.
Operation     | Detail     |
---|---|
The display will then show the following message:     | AUTO SCROLL TIME 3.0 Seconds     |
Illustration 9 | g00844793 |
This is the duration that each instrument will be displayed for during the automatic scrolling. Use the UP key and the DOWN key in order to set the duration to the required value.
Illustration 10 | g00844409 |
Mode Select Key |
When the setting is correct, press the MODE SELECT KEY in order to view the next function.
Operation     | Detail     |
---|---|
The display will then show the following message:     | INDICATIONS ON LCD YES     |
Illustration 11 | g00844793 |
Digital inputs that are configured as indications can be viewed on the display by pressing the UP key or the DOWN key when the INFORMATION MODE is active. To disable this function, set to "NO" by pressing the UP key or the DOWN key.
Illustration 12 | g00844409 |
Mode Select Key |
When correct, press the MODE SELECT KEY in order to view the next function.
Operation     | Detail     |
---|---|
The display will show the following message:     | ABANDON CHANGES AND EXIT     |
Illustration 13 | g00844793 |
In order to exit the OPERATOR CONFIGURATION MODE and store the changes you have made, press the UP key or the DOWN key.
Illustration 14 | g00844409 |
Mode Select Key |
If you wish to save the changes you have made to the configuration, press the MODE SELECT KEY.
Operation     | Detail     |
---|---|
The display will show the following message:     | SAVE CHANGES AND EXIT     |
Illustration 15 | g00844793 |
In order to exit the OPERATOR CONFIGURATION MODE and store the changes you have made, press the UP key or the DOWN key.
The module will return to the INFORMATION MODE, and the OPERATOR CONFIGURATION MODE INDICATOR will extinguish.