3500B and 3500B High Displacement Generator Set Engines Caterpillar


Engine Control Switch (ECS) (EMCP II)

Usage:

3508B 5KW
System Operation Description:

The engine control switch (ECS) is used by the operator for manually controlling the engine. The ECS has four positions and each position connects to a corresponding input of the GSC+. The selected position of the ECS connects the corresponding input of the GSC+ to the -Battery terminal. At any time, only one of these four positions (inputs) is connected to the -Battery terminal.

Each position of the ECS places the engine in a different mode. The four positions and the corresponding modes are described in the following paragraphs.

"OFF/RESET" - The engine is shut down and the GSC+ is reset. The upper display and fault indicators on the left side are temporarily cleared. The GSC+ turns OFF unless a jumper is installed at the ECS. The jumper electrically connects terminal "6" to terminal "9" on the ECS.

"AUTO" - The engine starts and the engine runs when the remote start/stop initiate contact closes the start input that is located on the GSC+. The GSC+ closes the remote start/stop initiate contact to the battery negative terminal "B-". Also, the engine starts and the engine runs when the customer communication module (CCM) sends a remote start command. At this time, the GSC+ starts the engine. The engine runs normally until the remote start/stop initiate contact opens. Also, the engine runs normally until the customer communication module (CCM) sends a remote stop command. The engine enters a cooldown period. After the cooldown period, the engine is shut down. The GSC+ shows diagnostic codes on the upper display and on the fault indicators as the diagnostic code occurs. The GSC+ is ON with the ECS in this position.

"MAN/START" - The engine starts and the engine runs until the operator turns the ECS to the "OFF/RESET" or the "COOLDOWN/STOP". The engine starts and the engine runs until the GSC+ detects a shutdown fault. The GSC+ shows diagnostic codes on the upper display and on the fault indicators as the diagnostic code occurs. The GSC+ is ON with the ECS in this position.

"COOLDOWN/STOP" - The engine enters a cooldown period. The cooldown period is programmable from 0 to 30 minutes. After the cooldown period elapses, the engine is shut down. The GSC+ shows diagnostic codes on the upper display and on the fault indicators as the diagnostic code occurs. The GSC+ is ON with the ECS in this position.

Note: The remote start/stop contact is connected to the GSC+ start input via a terminal strip. Wire number 57 makes the connection from the terminal strip to the GSC+ start input. Before troubleshooting, disconnect the remote start/stop initiate contacts from the terminal strip.

Note: Diagnostic codes are created when the harness connector is disconnected from the GSC+ during these troubleshooting procedures. Clear these created diagnostic codes after the particular problem is corrected and the particular diagnostic code is cleared.

The possible causes of a CID 0336 FMI 02 are listed below.

  • None of the inputs from the ECS to the GSC+ are connected to ground.

  • More than one of the inputs from the ECS to the GSC+ is connected to the -Battery terminal at the same time. The one exception is the start input. The start input of the GSC+ is also connected to the remote start/stop initiate contact. The contact is controlled by the customer. The GSC+ will then accept a connection from the battery negative at the start input. Other inputs from the ECS are also received.

The CID 0336 FMI 02 is the only ECS diagnostic code that is detected by the GSC+. Clear the diagnostic code from the fault log after troubleshooting is complete. The GSC+ treats a CID 0336 FMI 02 as a shutdown fault. Use these procedures for an active diagnostic code or an inactive diagnostic code.




Illustration 1g01023143

Typical circuit with EMCP II

Test Step 1. Check for an Open Circuit in the OFF/RESET Position.

  1. If equipped, disconnect the remote start/stop initiate contacts from the terminal strip in the customer connection box.

  1. Disconnect the harness connector from the GSC+.

  1. Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.

  1. Turn the ECS to the OFF/RESET position.

  1. At the GSC+ harness connector, measure the resistance from contact "39" to the -Battery terminal of the relay module. Measure the resistance from contacts "32", "33" and "40" to the -Battery terminal. Make a note of the resistances that are measured.

Expected Result:

The resistance that is measured from contact "39" to the -Battery terminal of the relay module is 5 Ohms or less. The resistance that is measured from contacts "32", "33" and "40" to the -Battery terminal is greater than 5000 Ohms.

Results:

  • OK - All resistance measurements are correct. Proceed to Test Step 2.

  • Not OK - The resistance measurements are not correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed.

    Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the -Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after troubleshooting is complete.

    Stop.

Test Step 2. Check for an Open Circuit in the AUTO Position.

  1. If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the customer connection box.

  1. The harness connector remains disconnected from the GSC+.

  1. Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.

  1. Place the ECS in the AUTO position. Measure the resistance from contact "40" of the GSC+ harness connector to the -Battery terminal of the relay module. Measure the resistance from contacts "32", "33" and "39" to the -Battery terminal. Make a note of the resistances that are measured.

Expected Result:

The resistance that is measured from contact "40" to the -Battery terminal of the relay module is 5 Ohms or less. The resistance that is measured from contacts "32", "33" and "39" to the -Battery terminal is greater than 5000 Ohms.

Results:

  • OK - The resistance measurements are correct. Proceed to Test Step 3.

  • Not OK - The resistance measurements are not correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed.

    Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the -Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed.

    Stop.

Test Step 3. Check for an Open Circuit in the MAN/START Position.

  1. If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the customer connection box.

  1. The harness connector remains disconnected from the GSC+.

  1. Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.

  1. Place the ECS in the MAN/START position. Measure the resistance from contact "33" of the GSC+ harness connector to the -Battery terminal of the relay module. Measure the resistance from contacts "32", "39" and "40" to the -Battery terminal. Make a note of the resistances that are measured.

Expected Result:

The resistance that is measured from contact "33" to the -Battery terminal of the relay module is 5 Ohms or less. The resistance that is measured from contacts "32", "39" and "40" to the -Battery terminal is greater than 5000 Ohms.

Results:

  • OK - The resistance measurements are correct. Proceed to Test Step 4.

  • Not OK - The resistance measurements are not correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed.

    Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the -Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed.

    Stop.

Test Step 4. Check for an Open Circuit in the COOLDOWN/STOP Position.

  1. If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the customer connection box.

  1. The harness connector remains disconnected from the GSC+.

  1. Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.

  1. Place the ECS in the COOLDOWN/STOP position. Measure the resistance from contact "32" of the GSC+ harness connector to the -Battery terminal of the relay module. Measure the resistance from contacts "33", "39" and "40" to the -Battery terminal. Make a note of the resistances that are measured.

Expected Result:

The resistance that is measured from contact "32" to the -Battery terminal of the relay module is 5 Ohms or less. The resistance that is measured from contacts "33", "39" and "40" to the -Battery terminal is greater than 5000 Ohms.

Results:

  • OK - The resistance measurements are correct. Proceed to Test Step 5.

  • Not OK - The resistance measurements are not correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed.

    Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the -Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed.

    Stop.

Test Step 5. Check for Active Diagnostic Codes.

  1. Reconnect all of the harness connectors.

  1. Clear all diagnostic codes from the fault log.

  1. Operate the engine.

  1. Determine if the diagnostic code is active.

Expected Result:

The diagnostic code is not active.

Results:

  • OK - The diagnostic code is not active.

    Repair: The problem does not exist at this time. The initial problem was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. If the problem is intermittent, refer to the diagnostic functional test Troubleshooting, "Inspecting Electrical Connectors".

    Stop.

  • Not OK - The diagnostic code is active.

    Repair: The problem has not been corrected. It is unlikely that the ECS has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECS.

    Stop.

Caterpillar Information System:

Electronic Modular Control Panel II+ (EMCP II+) Instrument Panel
3054, 3054B and 3056 Marine Engines Fuel Injection Pump - Install - Delphi
3054, 3054B and 3056 Marine Engines Fuel Injection Pump - Remove - Delphi
3054, 3054B and 3056 Marine Engines Engine Oil Filter Base - Install - 3056 Engine
3054, 3054B and 3056 Marine Engines Engine Oil Filter Base - Remove - 3056 Engines
3054, 3054B and 3056 Marine Engines Engine Oil Filter Base - Install - 3054 and 3054B Engines
3054, 3054B and 3056 Marine Engines Engine Oil Filter Base - Remove - 3054 and 3054B Engines
G3500 Engines Exhaust Manifold - Dry
3512B Marine Auxiliary Engine Engine Oil Pan
G3600 Engines Cylinder Head, Valves, Valve Springs and Valve Seat Inserts
3500 Spark Ignited Engines Exhaust Manifold - Water cooled
Generator Set Control Panel for Switchgear Conversion Related Components
3034 Marine Engine - Installation Guide Engine Mounting
3054 and 3056 Industrial and Generator Set Engines Fuel System - Prime
G3600 Engines Engine Speed/Timing Sensor - Clean/Inspect
120H and 135H Motor Graders Alternate Exit
G3520C and G3520E Engines Water Temperature Regulator
3512B Marine Auxiliary Engine System Overview
Electronic Modular Control Panel II+ (EMCP II+) Starting Motor Magnetic Switch - Test
3054, 3054B and 3056 Marine Engines Heat Exchanger - Remove - 3054 and 3054B Engines
3034 Marine Engine Fuel System Secondary Filter - Replace
Electronic Modular Control Panel II (EMCP II) GSC CID 0441 - FMI 12 (for MUI Engines)
797 Off-Highway Truck Power Train Final Drive - Assemble
3054, 3054B and 3056 Marine Engines Heat Exchanger - Install - 3054 and 3054B Engines
Back to top