Recommended
The following equipment is recommended:
- The Fluke 741B Process Calibration is desired. 163-0096 Diagnostic and Calibration Tool
- The 4C-4029 Adjusting Tool
- The Fluke 87 9U-7330 Digital Multimeter
- The Caterpillar Multimeter is also acceptable. 6V-7070 Digital Multimeter
- Power Supply
The attachments for the Fluke multimeter are in the following list:
- Thermocouple Module 80TK is for reading thermocouples.
- Immersion Probe 80PK2A can be used with self-sealing adapters.
- 4C-6095 Plug
- 6V-9131 Thermocouple Probe (K Type)
- 7X-7481 Wire (K Type)
General Diagnostic Tools For the 3600
Reference Engine News October 1990"Engine Commissioning and Diagnostic Tooling Kit".
The following tools are used for measuring the pressures of the engine. The tools are also use for measuring the temperatures of the engine.
The following list contains the self-sealing adapters that are used for the installation of test ports in piping systems. The sizes of the adapters and the quantities of the adapters depend on the number of test ports that are needed.
- 5P-2725 Probe Seal Adapter
- 5P-3591 Probe Adapter
- 4C-4545 Probe Adapter Group
- 1U-8865 Infrared Thermometer
- 139-2788 Crimping Tool
A Carrier-Oehler Calibration Pump is used in order to calibrate the setup for the alarms. The pump is also used in order to calibrate the shutdown setup.
Contact information for the calibration pump:
Carrier-Oehler CompanyP.O. Box 40
16965 S. Vincennes
South Holland, Illinois USA 60473
ph: (708) 339-8200, fax: (708) 339-9830