Recirculation Air Sensor
Illustration 1 | g01284768 |
Partial electrical schematic (1) Connector (2) Recirculation Air Sensor (3) Terminal 8 (4) Terminal 9 |
Diagnostics
Disconnect connector (1). Measure the resistance between terminal 8 (3) and terminal 9 (4). If the resistance is approximately the values that are given in the following table, the sensor is good.
Temperature     | Resistance     |
0 °C (32 °F)     |
7.2Ω     |
25 °C (77 °F)     |
2.2Ω     |
If the resistance is different, the sensor is bad. Replace the sensor.
Sunlight Sensor
Illustration 2 | g01285823 |
Partial electrical schematic (1) Sunlight sensor (2) Connector (3) Terminal 10 (4) Terminal 11 |
Diagnostics
Connect positive tester bar to the Y/W terminal (3) and the negative tester bar to the Y/G terminal (4) and make sure that the voltage is the following:
- The upper surface of the sensor is exposed to solar radiation: 0.3 V approximate
- The upper surface of the sensor is not exposed to the solar radiation because the sensor is covered with the hand: 0 V approximate
Note: Perform the test while the main power switch or the auto control switch on the control panel is pushed in order to operate the heater. Perform the test while the connector for the solar radiation sensor is connected to a harness. It is impossible to make sure of the variation in the voltage with a flashlight or a fluorescent light.
Fresh Air Sensor
Illustration 3 | g01285851 |
Partial electrical schematic (1) Fresh air sensor (2) Connector (3) Terminal 12 (4) Terminal 13 |
Disconnect connector (2). Measure the resistance between terminal 12 (3) and terminal 13 (4). If the resistance is approximately the values that are given in the following table, the sensor is good.
Temperature     | Resistance     |
0 °C (32 °F)     |
11.7Ω     |
25 °C (77 °F)     |
4.0Ω     |
If the resistance is different, the sensor is bad. Replace the sensor.
Water Temperature Sensor
Illustration 4 | g01285907 |
Partial electrical schematic (1) Connector (2) Water temperature sensor (3) Terminal 14 (4) Terminal 15 |
Diagnostics
Disconnect connector (1). Measure the resistance between terminal 14 (3) and terminal 15 (4). If the resistance is approximately the values that are given in the following table, the sensor is good.
Temperature     | Resistance     |
50 °C (122 °F)     |
3.9Ω     |
If the resistance is different, the sensor is bad. Replace the sensor.
Evaporator Sensor
Illustration 5 | g01285958 |
Partial electrical schematic (1) Connector (2) Evaporator sensor Frost (3) Terminal 16 (4) Terminal 17 |
Diagnostics
Disconnect connector (1). Measure the resistance between terminal 16 (3) and terminal 17 (4). If the resistance is approximately the values that are given in the following table, the sensor is good.
Temperature     | Resistance     |
0 °C (32 °F)     |
7.2Ω     |
25 °C (77 °F)     |
2.2Ω     |