Illustration 1 | g00362864 |
Illustration 2 | g00367673 |
6V-0890 Electric Starting Motor
When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25°C (77°F)
- Speed ... 6950 ± 1650 rpm
- Current draw ... 115 ± 25 amp
- Voltage ... 23 V
- Current draw ... 115 ± 25 amp
(1) Tighten the nut on the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(2) Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(5) Tighten the nut on the motor terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
125-6533 Solenoid
Current consumption at 25°C (77°F)
- Pull-in windings at 20V ... 49.3 ± 3.3 Amp
- Hold-in windings at 20V ... 6.8 Amp maximum
Illustration 3 | g00508643 |
6V-0501 Electric Starting Motor
6V-0508 Electric Starting Motor
When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25°C (77°F)
- Speed ... 6500 ± 1000 rpm
- Current draw ... 87.5 ± 12.5 amp
- Voltage ... 30 V
- Current draw ... 87.5 ± 12.5 amp
(1) Tighten the nut on the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(2) Tighten the nut on the motor terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(5) Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
3T-5051 Starting Motor Solenoid
Current consumption at 25°C (77°F)
- Pull-in windings at 32V ... 41 ± 3 Amp
- Hold-in windings at 32V ... 6.3 Amp
Illustration 4 | g00511888 |
6V-0927 Electric Starting Motor
When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25°C (77°F)
- Speed ... 6950 ± 1650 rpm
- Current draw ... 115 ± 25 amp
- Voltage ... 23 V
- Current draw ... 115 ± 25 amp
(1) Tighten the nut on the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(2) Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(5) Tighten the nut on the motor terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
125-6533 Solenoid Assembly
Current consumption at 25°C (77°F)
- Pull-in windings at 20V ... 49.3 ± 3.3 Amp
- Hold-in windings at 20V ... 6.8 Amp
Illustration 5 | g00286676 |
Illustration 6 | g00286677 |
7T-0794 Electric Starting Motor
When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25°C (77°F)
- Speed ... 5500 rpm minimum
- Current draw ... 140 Amp maximum
- Voltage ... 24 V
- Current draw ... 140 Amp maximum
(1) Tighten the nut on the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(2) Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(5) Tighten the nut on the motor terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
9X-0332 Solenoid Kit
Current consumption at 25°C (77°F)
- Pull in windings at 24V ... 51 Amp
- Hold in windings at 24V ... 7 Amp
Illustration 7 | g00286672 |
Illustration 8 | g00286673 |
8C-3644 Electric Starting Motor
When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25°C (77°F)
- Speed ... 7643 ± 1683 rpm
- Current draw ... 67.5 ± 7.5 amp
- Voltage ... 23 V
- Current draw ... 67.5 ± 7.5 amp
(1) Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(2) Tighten the nut on the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(5) Tighten the nut on the motor terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 8 ± 3 N·m (71 ± 27 lb in)
9X-9511 Solenoid Assembly
Current consumption at 25°C (77°F)
- Pull in windings at 20V ... 56.5 ± 4.5 Amp
- Hold in windings at 20V ... 14.6 Amp
Illustration 9 | g00507849 |
Illustration 10 | g00507851 |
9X-4452 Electric Starting Motor
When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25°C (77°F)
- Speed ... 3300 rpm minimum
- Current draw ... 80 Amp maximum
- Voltage ... 23.5 V
- Current draw ... 80 Amp maximum
(1) Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(2) Tighten the nut on the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(3) Tighten the nut on the motor terminal to the following torque. ... 30.5 ± 3.5 N·m (22.50 ± 2.58 lb ft)
(4) Tighten to the following torque. ... 1.5 ± 0.5 N·m (13.28 ± 4.43 lb in)
(5) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 17.5 ± 2.5 N·m (12.91 ± 1.84 lb ft)
3E-0135 Solenoid
Current consumption at 25°C (77°F)
- Pull in windings at 24V ... 103 Amp
- Hold in windings at 24V ... 19 Amp